Soil Stabilization & Settlement Control · Injection Resin

AP Fill 700 Polyurethane Injection Resin

A single-component resin thin enough to permeate sandy soil and fill a void, with a set time adjustable down to 20 seconds when water is already moving.

NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.

Soil permeation grouting

Void filling

Fast set

Water cutoff

What it is

A thin, fast resin for permeating soil and filling voids

AP Fill 700 is a single-component, water-activated, hydrophobic, closed-cell polyurethane injection resin used to permeation grout sandy soil, fill voids, and cut off underground water. Its published pre-activated mix viscosity is 120 cP, thin enough to travel through the pore spaces between sand grains rather than pushing the soil aside.

Set time is the other half of the product. It is adjustable down to about 20 seconds using Alchatek Cat 106 for regular speed or Cat 107 for fast, which is what lets it hold in ground where water is already running. Cured, it is semi-rigid and closed cell.

Where it is used

What AP Fill 700 is used for

AP Fill 700 sits in the Soil Stabilization & Settlement Control solution family, and is also used for water cutoff work.

  • Permeation grouting in sandy soil

  • Consolidating loose soil

  • Filling voids under concrete slabs

  • Filling voids behind concrete structures

  • Cutting off underground water flows

  • Cutting off high-flow water leaks

How it works

How AP Fill 700 binds sandy soil instead of displacing it

AP Fill 700 is injected with catalyst into the soil or void, where it travels through the pore spaces, reacts with the water present, and cures into a closed-cell semi-rigid foam that binds the material together. The 120 cP pre-activated mix viscosity is what makes permeation possible: a thicker resin fractures the ground and creates lenses instead of filling between the grains.

Reaction speed is set by catalyst and dosage, so the crew matches it to how fast water is moving. Cat 106 runs from 25 seconds to initial reaction at 2 percent down to 8 seconds at 10 percent. Cat 107 holds a 5 second initial reaction throughout while full rise tightens from 30 seconds to 16. Cured, the foam is semi-rigid, with published tensile elongation of 2.90 percent, so this is a binding and filling resin rather than one for a crack that keeps working.

Technical specifications

Published properties


Resin and cured foam

Property

Value

Method

Pre-activated mix viscosity

120 cP (120 mPa·s)

TDS

Compressive strength, with fine sand

2,050 psi, or 295,200 psf (14,100 kPa)

ASTM C-39

Tensile strength

45 psi, or 6,480 psf (310 kPa)

ASTM D-1623

Tensile elongation

2.90%

ASTM D-1623

Shrinkage

Negligible

ASTM D-1042 / D-756


Reaction time by catalyst & dosage

Catalyst

Dosage

Initial reaction

Full rise

Cat 106

2%

25 sec

1 min 50 sec

Cat 106

5%

15 sec

1 min 27 sec

Cat 106

10%

8 sec

30 sec

Cat 107

5%

5 sec

30 sec

Cat 107

7.5%

5 sec

22 sec

Cat 107

10%

5 sec

16 sec


Handling & certification

Property

Value

Method / Note

Composition

Single component plus catalyst; water activated, hydrophobic, closed cell, semi-rigid

TDS / product page

Application temperature

41–95°F (5–35°C)

Not on this data sheet; confirmed by Alchatek, to be added to the TDS

Storage

50–80°F (10–26°C)

TDS

Shelf life

24 months, unopened, within storage range

TDS

Packaging

5-gallon pail, 50-gallon drum, and 250-gallon tote

Product page

Certification

NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions on wetted surface area and minimum tank volume. See the certificate.

TDS Rev. 5/19/2026 and certified product listing

Reaction times are published at the catalyst dosages shown. Source: AP Fill 700 Technical Data Sheet, Rev. 5/19/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets and certificates

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.

Compatible equipment & accessories

What you need to inject AP Fill 700

  • Alchatek Cat 106 and Cat 107, the catalysts for this resin. Cat 106 is the regular speed, Cat 107 the fast. Dosage sets the reaction. View catalysts 

  • Single-component airless injection pump, recommended for AP Fill 700. View pumps 

  • Injection probes and packers, for placing the resin at depth in soil and behind structures. View accessories 

  • Alchatek Pump Flush, reusable, biodegradable pump flush. Given how fast this resin can be set to react, stage the flush before injecting. View flush 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Stabilizing soil and filling voids, and cutting off water while it does. It is used for permeation grouting sandy soil, consolidating loose soil, filling voids under slabs and behind concrete structures, and cutting off underground water flows and high-flow leaks.

By permeation grouting. The resin is thin enough to travel through the pore spaces between sand grains rather than pushing the soil aside, then it reacts with water present and cures into a closed-cell foam that binds the grains together.

As fast as 20 seconds, per the published advantages, and it is adjustable. With Alchatek Cat 107 at 10 percent the published initial reaction is 5 seconds with full rise at 16 seconds. With Cat 106 at 2 percent it is 25 seconds to initial reaction with full rise at 1 minute 50 seconds.

Alchatek Cat 106 for regular speed or Cat 107 for fast speed. Dosage sets the reaction. The data sheet advises against using Cat 106 below 2 percent or Cat 107 below 5 percent.

Published pre-activated mix viscosity is 120 cP. That is thin for an injection resin, which is what allows it to permeate sandy soil and travel through a void rather than stopping at the face of it.

Published compressive strength is 2,050 psi, or 295,200 psf, when tested with fine sand by ASTM C-39. Tensile strength is 45 psi, or 6,480 psf, and tensile elongation is 2.90 percent by ASTM D-1623, with negligible shrinkage. The compressive figure is a sand-filled result, so read it in that context.

No. It is semi-rigid and cures closed cell, with published tensile elongation of 2.90 percent. It is built to bind soil and fill volume, not to follow a crack that keeps moving.

AP Fill 700 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The listing carries use restrictions on wetted surface area and minimum tank volume, so read the certificate and confirm the certification is current before specifying.

5-gallon pails, 50-gallon drums, and 250-gallon totes.

A single-component airless injection pump is recommended, along with injection probes and packers, Alchatek Cat 106 or Cat 107, and Alchatek Pump Flush for shutdown. Given how fast this resin can be set to react, stage the flush before injecting rather than after.

Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.

Proof & Verification

APFILL700-PB-01

Deep Soil Stabilization at Shopping Center

A settling gravel-filled trench between two underground parking garages in Salt Lake City tore buried power lines. AP Fill 700 was injected through tubes 30 feet deep to stabilize it.
View case study

APFILL700-PB-02

Slot 2: Performance Data Point or Credential

empty, Alchatek to supply
Case Studies

APFILL700-PB-03

Slot 3: Documentation Reference

empty, Alchatek to supply
Case Studies

Sandy soil that needs binding, or a void taking water faster than a slower resin can fill it? Talk the condition through before the rig goes out.

For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.