Leak Sealing & Water Control · Injection Resin

Spetec F400 Polyurethane Injection Resin

A single-component hydrophobic resin that reacts with the water in a leaking crack, expands into a closed-cell foam, and cures flexible so the seal holds where the structure moves.

NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.

Hydrophobic

Closed cell

Crack & joint injection

Curtain grouting

What it is

A hydrophobic, closed-cell resin for leaks in cracks and joints that move

Spetec F400 is a single-component, hydrophobic, closed-cell polyurethane injection resin used to shut off active water leaks in concrete, brickwork, and sewers. It reacts with the water already present, expands, and cures into a flexible foam that fills the crack or joint and seals the leak. Because the cured foam stays flexible, it holds up where movement or settlement occurs.

F400 is solvent free and phthalate free, and its published properties list the cured foam as chemically resistant. Soaked into oakum, an oil-free compressible fibrous packing, it also seals wider and irregular joints.

Where it is used

What F400 is used for

F400 is part of the Spetec Leak Seal Systems line and sits in the Leak Sealing & Water Control solution family.

  • Leaks in concrete, brickwork, and sewers where movement or settlement occurs

  • Foundation water cut-off: diaphragm walls, sheet piling, and secant piles

  • Water-carrying cracks and joints in tunnel segments

  • Curtain grouting behind tunnel, concrete, and sewer walls

  • Joint sealing with oakum soaked in F400

  • Water cut-off membranes and liners in tunnels

How it works

How F400 seals a crack that is already leaking

F400 is injected into a wet crack or joint, where it reacts with the water present, expands into a closed-cell foam, and cures into a flexible seal. Its low viscosity, 350 cP at 77°F, lets it travel into tight cracks before it reacts. Because the resin is hydrophobic, the cured foam does not take water back up, and the data sheet lists it as closed cell and shrink free.

Reaction time is the variable a crew controls. Gen Cat and Gen Cat Fast set how quickly the resin reacts, and the published table runs from 14 seconds to 165 seconds depending on which catalyst is used and how cold the structure is. Colder concrete slows the reaction, so catalyst choice follows site temperature rather than habit.

Technical specifications

Published properties


Physical properties

Property

Value

Method

Appearance, uncured

Clear amber liquid

-

Viscosity at 77°F

350 cP (350 mPa·s)

ASTM D4878

Density at 77°F

64.3 lb/ft³

ASTM D1475

Structure, cured

Closed cell, flexible, shrink free

TDS

Elongation at break, cured

100%

ASTM D3574-03


Catalyst options & reaction time

Property

Gen Cat

Gen Cat Fast

Viscosity at 77°F

75 cP

70 cP

Density at 77°F

65.5 lb/ft³

65.5 lb/ft³

Flash point

Not published

313°F

Reaction time at 77°F

17 to 73 seconds

14 to 47 seconds

Reaction time at 59°F / 60°F

24 to 104 seconds

14 to 59 seconds

Reaction time at 41°F / 40°F

60 to 165 seconds

21 to 72 seconds


Handling & certification

Property

Value

Method / Note

Composition

Single component, hydrophobic, water reactive; solvent free and phthalate free

TDS / product page

Application temperature

41–95°F

TDS

Storage

50–80°F (10–26°C)

TDS

Shelf life

24 months, unopened, within storage range

TDS

Certification

NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions on wetted surface area and minimum tank volume. See the certificate.

TDS Rev. 3/9/2026 and NSF certified product listing

Reaction times are measured at 10% catalyst. The data sheet publishes the two catalysts at slightly different test temperatures, shown here as the paired values. Source: Spetec F400 Technical Data Sheet, Rev. 3/9/2026, and the NSF/ANSI/CAN 61 and 372 certified product listing. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets and application guides

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.

Compatible equipment & accessories

What you need to inject F400

  • Single-component airless injection pump, recommended for F400. View pumps 

  • High-pressure crack-injection valves and packers, for setting and injecting cracks and joints. View accessories 

  • Alchatek Gen Cat and Gen Cat Fast, the catalysts that set F400 reaction time to the site temperature. View catalysts 

  • INJECTR Series Cartridges, cartridge format for small-volume and access-limited work. View cartridges 

  • Alchatek Pump Flush and Soak 130, reusable biodegradable pump flush for shutdown, and the solvent that cleans cured polyurethane off equipment. View flush  View solvent 

  • Oakum, oil-free compressible fibrous packing, forced into a joint or opening to provide a backing, seal, or carrier for the resin. It has to be oil free, because oiled fiber will not absorb the resin. View 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Yes. F400 is water reactive. It reacts with the water already in the crack or joint, expands into a closed-cell foam, and cures into a flexible seal. Water present at the time of injection is the condition it is built for, not something to dry out first.

F400 is hydrophobic. It reacts with water to expand and cure, and the cured closed-cell foam does not take water back up. Its Technical Data Sheet lists the cured material as closed cell, flexible, and shrink free.

F400 is a single-component resin, and reaction time is set with Alchatek Gen Cat or Gen Cat Fast. The published reaction table is measured at 10 percent catalyst and runs from 14 seconds with Gen Cat Fast at 77 degrees F to 165 seconds with Gen Cat at 41 degrees F.

Per its current Technical Data Sheet, F400 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The NSF listing carries use restrictions on wetted surface area and minimum tank volume, so read the certificate and confirm the certification is current before specifying.

Concrete, brickwork, and sewers where movement or settlement occurs; foundation elements such as diaphragm walls, sheet piling, and secant piles; water-carrying cracks and joints in tunnel segments; curtain grouting behind walls; and water cut-off membranes and liners in tunnels.

Yes. The cured foam is flexible and closed cell, with elongation at break published at 100 percent by ASTM D3574-03. That suits cracks and joints where movement or settlement may occur.

F400 is a hydrophobic, closed-cell resin for cracks and joints that move. GT350 is an MDI-based hydrophilic resin for wet, dynamic cracks and joints. GT500 is a closed-cell hydrophilic resin with low viscosity and high elongation, for hairline cracks and oakum gaskets.

The Technical Data Sheet gives an application range of 41 to 95 degrees F. Reaction time lengthens as temperature drops, so catalyst choice follows site temperature: at 41 degrees F with Gen Cat the published reaction time runs 60 to 165 seconds.

A single-component airless injection pump is recommended, along with crack-injection valves and packers, Alchatek Gen Cat to set reaction time, and a pump flush or cleaning solvent for shutdown. F400 is also available in INJECTR Series cartridges.

Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.

Yes. Oakum is an oil-free compressible fibrous packing that is soaked in F400 and packed into the joint. It has to be oil free, because oiled fiber will not absorb the resin. The soaked oakum holds the resin in place while it reacts with water and expands, which is what lets wider and irregular joints be sealed.

No. They are the same product. Alchatek dropped PUR from the name, so older data sheets, labels, and purchase orders may still read Spetec PUR F400. The resin itself did not change.

Proof & Verification

F400-PB-01

Pat Mayse Dam Conduit Leak Sealing

Gerace Construction was contracted to repair and seal leaks in the discharge conduit at the Pat Mayse Dam, under USACE oversight requiring a manufacturer's representative on-site during grout injection.
View case study

F400-PB-02

Slot 2: Performance Data Point or Credential

empty, Alchatek to supply
Case Studies

F400-PB-03

Slot 3: Documentation Reference

empty, Alchatek to supply
Case Studies

Choosing between a hydrophobic and a hydrophilic resin for a leak that is already running? Talk the condition through before you commit to a method.