Leak Sealing & Water Control · Injection Resin
Spetec H200 Polyurethane Injection Resin
A single-component semi-rigid resin with a set time as fast as 20 seconds, for cutting off water that is moving too fast to wait on a slower grout.
NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.
Hydrophobic
Semi- rigid
Fast set
Gushing leaks
On this page:
What it is
The fast one, for water that will not wait
Spetec H200 is a single-component, water-activated, hydrophobic, closed-cell polyurethane injection resin that cures semi-rigid and can be set to react in as little as 20 seconds. It is used to cut off high-flow leaks and underground water, and to fill voids behind and under concrete. Its published advantage is a very low viscosity, so it travels while the water is still moving.
H200 uses its own catalysts, Alchatek Cat 106 and Cat 107, rather than the Gen Cat catalysts that go with H100 and HighFoamer. Dosage sets the reaction, and the data sheet gives a minimum dosage for each.
Where it is used
What H200 is used for
H200 is part of the Spetec Leak Seal Systems line and sits in the Leak Sealing & Water Control solution family.
Cutting off high-flow water leaks
Cutting off underground water flows
Filling voids behind concrete structures
Filling voids under concrete slabs
Permeation grouting in sandy soil
Consolidating loose soil
Municipal work such as manholes and lift stations
How it works
How H200 keeps up with water that is already moving
H200 is injected with catalyst into the flow, where it reacts with the water present and expands into a closed-cell semi-rigid foam that cuts off the flow. Speed is the point. With Cat 107 at 10 percent the published initial reaction is 5 seconds and full rise is 16 seconds, which is fast enough to hold in moving water rather than being washed out of the opening.
The two catalysts cover different working windows. Cat 106 runs slower, from 25 seconds to initial reaction at 2 percent down to 8 seconds at 10 percent. Cat 107 is quick throughout, holding a 5 second initial reaction while full rise tightens from 30 to 16 seconds as dosage rises. Cured, the foam is semi-rigid: published tensile elongation is 2.90 percent, so this is a cutoff and void-filling resin rather than one for a crack that keeps working.
Technical specifications
Published properties
Cured foam
Property | Value | Method |
|---|---|---|
Compressive strength, with fine sand | 2,050 psi, or 295,200 psf (14,100 kPa) | ASTM C-39 |
Tensile strength | 45 psi, or 6,480 psf (310 kPa) | ASTM D-1623 |
Tensile elongation | 2.90% | ASTM D-1623 |
Shrinkage | Negligible | ASTM D-1042 / D-756 |
Pre-activated mix viscosity | 120 cP (120 mPa·s) | TDS |
Reaction time by catalyst & dosage
Catalyst | Dosage | Initial reaction | Full rise |
|---|---|---|---|
Cat 106 | 2% | 25 sec | 1 min 50 sec |
Cat 106 | 5% | 15 sec | 1 min 27 sec |
Cat 106 | 10% | 8 sec | 30 sec |
Cat 107 | 5% | 5 sec | 30 sec |
Cat 107 | 7.5% | 5 sec | 22 sec |
Cat 107 | 10% | 5 sec | 16 sec |
Handling & certification
Property | Value | Method / Note |
|---|---|---|
Composition | Single component plus catalyst; water activated, hydrophobic, closed cell, semi-rigid; phthalate free | TDS / product page |
Application temperature | 41–95°F (5–35°C) | TDS |
Storage | 50–80°F (10–26°C) | TDS |
Shelf life | 24 months, unopened, within storage range | TDS |
Packaging | 5-gallon pail and 50-gallon drum | Product page |
Certification | NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions on wetted surface area and minimum tank volume. See the certificate. | TDS Rev. 7/30/2026 and certified product listing |
The data sheet publishes a pre-activated mix viscosity but no resin density or flash point, so neither is shown. Source: Spetec H200 Technical Data Sheet, Rev. 7/30/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.
Downloads
Data sheets, specifications, and procedures
Technical Data Sheet (TDS)
Published properties · PDF
Safety Data Sheet (SDS)
Handling & safety · PDF
NSF/ANSI/CAN 61 & 372 Certificate
Certified product listing · PDF
Specification, Chemical Grouting of Manholes
CSI format · PDF
Procedure, Manhole Infiltration Control
Field procedure · PDF
Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.
Compatible equipment & accessories
What you need to inject H200
Alchatek Cat 106 and Cat 107, the catalysts made for H200. These are not the Gen Cat catalysts used with H100 and HighFoamer. View catalysts
Single-component airless injection pump, recommended for H200. View pumps
Injection packers and valves, including the probe and packer setups used for void and curtain injection. View accessories
Alchatek Pump Flush and Soak 130, reusable biodegradable pump flush for shutdown, and the solvent that cleans cured polyurethane off equipment. Given how fast H200 sets, have the flush staged before injecting. View flush View solvent
Related articles & guides
Learn the method behind the product
Control Gushing Leaks with Curtain Grouting
Method explainer
Hydrophobic Polyurethanes vs Hydrophilic Polyurethanes
Chemistry comparison
Quickly Cut Off High-Flow Leaks with Spetec H200
Field walk-through
Frequently Asked Questions
Cutting off high-flow water fast, and filling the voids behind it. It is a water-activated, hydrophobic, closed-cell semi-rigid resin used on high-flow leaks, underground water flows, voids behind and under concrete, and loose soil.
As fast as 20 seconds, per the published advantages. The reaction is set by which catalyst is used and at what dosage. With Alchatek Cat 107 at 10 percent the published initial reaction is 5 seconds with full rise at 16 seconds. With Cat 106 at 2 percent it is 25 seconds to initial reaction with full rise at 1 minute 50 seconds.
Alchatek Cat 106 or Cat 107, which are specific to H200 and are not the Gen Cat catalysts used with H100 and HighFoamer. The data sheet advises against using Cat 106 below 2 percent or Cat 107 below 5 percent.
Published pre-activated mix viscosity is 120 cP, which is thin for an injection resin. That is why H200 is used where the water is moving fast and the resin has to travel before it reacts.
Published compressive strength is 2,050 psi when tested with fine sand, by ASTM C-39. Tensile strength is 45 psi and tensile elongation is 2.90 percent by ASTM D-1623, with negligible shrinkage. The compressive figure is a sand-filled result, so read it in that context.
No. H200 is semi-rigid and cures closed cell, with published tensile elongation of 2.90 percent. It is built to cut off flow and fill volume, not to follow a crack that keeps moving. For cracks and joints that move, the flexible resins in the line are the right choice.
H200 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The listing carries use restrictions on wetted surface area and minimum tank volume, so read the certificate and confirm the certification is current before specifying.
Cutting off high-flow leaks; filling voids behind concrete structures and under slabs; cutting off underground water flows; permeation grouting in sandy soil; and consolidating loose soil. In the field it is used often on municipal work such as manholes and lift stations.
A single-component airless injection pump is recommended, along with injection packers and valves, Alchatek Cat 106 or Cat 107, and a pump flush or cleaning solvent for shutdown. Given how fast H200 sets, plan the flush before injecting rather than after.
Speed and catalyst. Both are single-component hydrophobic semi-rigid resins for high-flow cutoff. H200 is the faster of the two, with a set time as fast as 20 seconds, it uses Cat 106 or Cat 107 rather than Gen Cat, and it publishes cured strength figures. H100 publishes an 18 times expansion figure, which H200 does not.
Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.
No. They are the same product. Alchatek dropped PUR from the name, so older data sheets, labels, and purchase orders may still read Spetec PUR H200. The resin itself did not change.
Proof & Verification
Water moving fast enough that a slower grout washes out? Talk the condition through before the crew mobilizes, and get the catalyst and dosage right the first time.
For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.