Leak Sealing & Water Control · Injection Resin

Spetec GT500 Polyurethane Injection Resin

A single-component hydrophilic resin thin enough to travel into a hairline crack, that cures into a closed-cell foam stretching to 350 percent before it breaks.

NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.

Hydrophilic

Closed cell

Crack & joint injection

Oakum gaskets

What it is

A thin, closed-cell hydrophilic resin for cracks that keep moving

Spetec GT500 is a single-component, hydrophilic polyurethane injection resin used to seal cracks, joints, and pipe penetrations in concrete by pressure injection. Its low viscosity, 215 cP, lets it travel into hairline cracks rather than stopping at the face. It reacts with the water present, expands about six times, and cures into a closed-cell foam that bonds tenaciously to wet concrete.

GT500 requires no catalyst and is phthalate free. It is also used to saturate dry oakum, an oil-free compressible fibrous packing, to build a flexible gasket for a pipe penetration, a joint, or a larger defect.

Where it is used

What GT500 is used for

GT500 is part of the Spetec Leak Seal Systems line and sits in the Leak Sealing & Water Control solution family.

  • Sealing cracks in concrete structures by pressure injection

  • Hairline cracks, wide cracks, and expansion joints

  • Pipe joints and pipe penetrations

  • Oakum gaskets: dry oakum saturated in GT500, for penetrations and larger defects

  • Structures in contact with drinking water, within the restrictions of the NSF listing

How it works

How GT500 gets into a crack too tight for a thicker resin

GT500 is injected under pressure into the crack, where it reacts with the water present, expands about six times, and cures into a flexible closed-cell foam that seals the crack. The reaction is staged and quick: an initial reaction at about 30 seconds, full rise at about 1.5 minutes, and full cure at 24 hours.

Two published properties do the work after that. The cured foam is closed cell and shrinks less than 2 percent, so it holds its volume in the crack instead of pulling away from the faces. Elongation at break is 350 percent, which is what lets the seal follow a crack that keeps opening and closing.

Technical specifications

Published properties


Physical properties, uncured

Property

Value

Method

Appearance

Clear amber liquid

-

Viscosity at 77°F

215 cP (215 mPa·s)

ASTM D4878

Density at 77°F

72.4 lb/ft³

EN ISO 2811-1


Reaction & cured properties

Property

Value

Method

Initial reaction

About 30 seconds

TDS

Full rise

About 1.5 minutes

TDS

Full cure

24 hours

TDS

Expansion

About 6x

TDS

Tensile strength

450 psi

ASTM D3574

Elongation at break

350%

ASTM D3574

Tear resistance

21 lb/in

ASTM D3574

Shrinkage

Less than 2%

ASTM D1042 / D756


Handling & certification

Property

Value

Method / Note

Composition

Single component, hydrophilic, closed cell; no catalyst required; phthalate free

TDS / product page

Application temperature

41–95°F

TDS

Storage

50–80°F

TDS

Shelf life

24 months, unopened, within storage range

TDS

Packaging

5-gallon pail

Product page

Certification

NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions on wetted surface area and minimum tank volume. See the certificate.

TDS Rev. 7/13/2026 and NSF certified product listing

Source: Spetec GT500 Technical Data Sheet, Rev. 7/13/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets and application guides

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.

Compatible equipment & accessories

What you need to inject GT500

  • Single-component airless injection pump, recommended for GT500. View pumps 

  • High-pressure crack-injection valves and packers, for setting and injecting cracks, joints, and pipe penetrations. View accessories 

  • Oakum, oil-free compressible fibrous packing, saturated in GT500 to build a flexible gasket for a penetration, a joint, or a larger defect. It has to be oil free, because oiled fiber will not absorb the resin. View 

  • Alchatek Pump Flush and Soak 130, reusable biodegradable pump flush for shutdown, and the solvent that cleans cured polyurethane off equipment. View flush  View solvent 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Yes. GT500 is hydrophilic and water reactive. It is injected under pressure into the crack, reacts with the water present, expands, and cures into a flexible closed-cell foam that seals the crack. It also bonds tenaciously to wet concrete.

No. GT500 is a single-component resin and requires no catalyst.

Its published viscosity is 215 cP at 77 degrees F, which is low for an injection resin. A thin resin travels into a hairline crack instead of stopping at the face of it, so the seal forms through the depth of the crack rather than across the surface.

GT500 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The listing carries use restrictions on wetted surface area and minimum tank volume, so read the certificate and confirm the certification is current before specifying.

About six times, per the published data. It expands as it reacts with water and cures into a closed-cell foam that shrinks less than 2 percent, so it holds its volume in the crack.

Yes. Published elongation at break is 350 percent by ASTM D3574, with tensile strength of 450 psi and tear resistance of 21 pounds per inch. That is what lets the seal follow a crack that keeps opening and closing.

The published sequence is an initial reaction at about 30 seconds, full rise at about 1.5 minutes, and full cure at 24 hours.

Cracks in concrete structures sealed by pressure injection, including hairline cracks, wide cracks, and expansion joints; pipe joints and pipe penetrations; and larger defects sealed with an oakum gasket saturated in the resin.

Yes, and it is one of the product's main uses. Oakum is an oil-free compressible fibrous packing. Dry oakum is saturated in GT500 and packed into the opening to build a flexible gasket for a pipe penetration, a joint, or a larger defect. It has to be oil free, because oiled fiber will not absorb the resin.

All three are flexible resins for cracks that move. GT500 is the thinnest of the three at 215 cP and cures closed cell with 350 percent elongation, which suits hairline cracks and oakum gaskets. GT350 is an MDI-based hydrophilic resin at 280 cP for wet, dynamic cracks and joints. F400 is hydrophobic, so its cured foam does not take water back up.

Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.

No. They are the same product. Alchatek dropped PUR from the name, so older data sheets, labels, and purchase orders may still read Spetec PUR GT500. The resin itself did not change.

Proof & Verification

GT500-PB-01

Water Treatment Plant Losing Two Million Gallons Per Day Due to Leaks

Twin 2-million gallon clearwell tanks in Chattanooga, Tennessee had shifted, loosening joints and water stops. Spetec GT500 was injected to seal the leaks.
View case study

GT500-PB-02

Slot 2: Performance Data Point or Credential

empty, Alchatek to supply
Case Studies

GT500-PB-03

Slot 3: Documentation Reference

empty, Alchatek to supply
Case Studies

Specifying GT500 for a hairline crack program, or deciding between a thin injection resin and an oakum gasket? Talk the condition through before you commit to a method.

For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.