Leak Sealing & Water Control · Injection Resin
Spetec H100 Polyurethane Injection Resin
A single-component semi-rigid resin that reacts in seconds and expands 18 times, for cutting off large, high-pressure water leaks in concrete.
NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.
Hydrophobic
Semi- rigid
Gushing leaks
Hot Shot cartridge
On this page:
What it is
The standard high-flow cutoff resin in the Spetec line
Spetec H100 is a single-component, hydrophobic, closed-cell polyurethane injection resin that expands 18 times and cures semi-rigid, used to cut off large, high-pressure water leaks in concrete. It is solvent free and phthalate free, and it is injected with Alchatek Gen Cat or Gen Cat Fast, where catalyst dosage sets how fast it reacts.
H100 is semi-rigid, not flexible, so it is built to fill an opening and hold rather than to follow a crack that keeps moving. It also comes in a 10.5 ounce Hot Shot cartridge, which lets a crew shut down a small active leak without setting up a pump.
Where it is used
What H100 is used for
H100 is part of the Spetec Leak Seal Systems line and sits in the Leak Sealing & Water Control solution family.
Water cutoff of large-flow and high-pressure leaks
Foundation water cut-off: diaphragm walls, sheet piling, and secant piles
Stabilization and cutoff of large cracks, voids, and gravel layers
Mines, tunnels, pipe jacking, drill and blast, and tunnel boring work
Injection combined with cement-based grout
Sewer leak sealing, and manhole injection
Probe grouting for below-grade pipes
Soil stabilization and anchors in porous geology
How it works
How H100 shuts down a leak running under pressure
H100 is injected with catalyst into the flowing water, where it reacts within seconds, expands 18 times, and cures into a closed-cell semi-rigid foam that fills the opening and stops the flow. The expansion figure holds across the published temperature range, so a crew can plan volume without adjusting for the weather.
Speed is what changes with conditions. At 10 percent catalyst, Gen Cat Fast at 77°F starts in 8 seconds and finishes in 36; Gen Cat at 40°F starts in 13 seconds and finishes in 56. Where the void is large rather than the flow high, Alchatek's own guidance is that HighFoamer, which expands up to 50 times, may be the more cost-effective choice.
Technical specifications
Published properties
Resin
Property | Value | Method |
|---|---|---|
Appearance | Brown liquid | - |
Viscosity at 77°F (25°C) | 210 cP (210 mPa·s) | ASTM D4878 |
Density at 77°F (25°C) | 66.8 lb/ft³ (1.07 kg/dm³) | EN ISO 2811-1 |
Expansion | 18x | TDS |
Reaction time at 10% catalyst, start to end
Catalyst | Temperature | Start | End |
|---|---|---|---|
Gen Cat | 40°F | 13 sec | 56 sec |
Gen Cat | 59°F | 10 sec | 49 sec |
Gen Cat | 77°F | 10 sec | 48 sec |
Gen Cat Fast | 41°F | 12 sec | 52 sec |
Gen Cat Fast | 60°F | 9 sec | 40 sec |
Gen Cat Fast | 77°F | 8 sec | 36 sec |
Handling & certification
Property | Value | Method / Note |
|---|---|---|
Composition | Single component plus catalyst; hydrophobic, closed cell, semi-rigid; solvent free and phthalate free | TDS / product page |
Application temperature | 41–95°F (5–35°C) | TDS |
Storage | 50–80°F | TDS |
Shelf life | 24 months, unopened, within storage range | TDS |
Packaging | 5-gallon pails and 10.5 oz Hot Shot cartridges | Product page |
Certification | NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions, including a minimum tank volume and an exclusion for pipe application. See the certificate. | TDS Rev. 7/30/2026 and NSF certified product listing |
Alchatek Gen Cat and Gen Cat Fast are yellow-orange liquids at 65.5 lb/ft³ with a 313°F flash point; viscosity at 77°F is 75 cP for Gen Cat and 70 cP for Gen Cat Fast. Source: Spetec H100 Technical Data Sheet, Rev. 7/30/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.
Downloads
Data sheets, specifications, and procedures
Technical Data Sheet (TDS)
Published properties · PDF
Safety Data Sheet (SDS)
Handling & safety · PDF
NSF/ANSI/CAN 61 & 372 Certificate
Certified product listing · PDF
Specification, Chemical Grouting of Manholes
CSI format · PDF
Procedure, Manhole Infiltration Control
Field procedure · PDF
Procedure, Pipe Leaks by Point Grouting
Field procedure · PDF
Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.
Compatible equipment & accessories
What you need to inject H100
Alchatek Gen Cat and Gen Cat Fast, the catalysts that set H100 reaction time. Published reaction data is measured at 10 percent. View catalysts
Single-component airless injection pump, recommended for H100. View pumps
Injection packers and valves, including the probe and packer setups used for curtain grouting and void injection. View accessories
Hot Shot cartridges, 10.5 oz format for shutting down a small active leak without a pump. View cartridges
Alchatek Pump Flush and Soak 130, reusable biodegradable pump flush for shutdown, and the solvent that cleans cured polyurethane off equipment. View flush View solvent
Related articles & guides
Learn the method behind the product
Control Gushing Leaks with Curtain Grouting
Method explainer
Hydrophobic Polyurethanes vs Hydrophilic Polyurethanes
Chemistry comparison
Spetec H100 Hot Shot Cartridge
Field walk-through
Filling Abandoned Pipes with Spetec H100
Field walk-through
Frequently Asked Questions
Large, high-pressure water leaks. It is a semi-rigid resin that reacts in seconds and expands 18 times to cut off flow in concrete, foundations, tunnels, sewers, and manholes. It is the standard high-flow cutoff resin in the Spetec line.
18 times, per the published reaction data, and that figure holds across the tested temperature range. If the void is large, Alchatek's own guidance is that HighFoamer, which expands up to 50 times, may be the more cost-effective choice.
Yes. Alchatek Gen Cat or Gen Cat Fast is used with H100, and dosage is how reaction time is set. The published reaction data is measured at 10 percent catalyst.
At 10 percent catalyst the published reaction starts in 8 to 13 seconds and finishes in 36 to 56 seconds, depending on the catalyst and the temperature. Gen Cat Fast at 77 degrees F is the quickest at 8 to 36 seconds; Gen Cat at 40 degrees F is the slowest at 13 to 56 seconds.
No. H100 is semi-rigid and cures closed cell. It is built to fill an opening and hold, not to follow a crack that keeps moving. For cracks and joints that move, the flexible resins in the line are the right choice.
H100 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The listing carries use restrictions, including a minimum tank volume and an exclusion for pipe application, so read the certificate and confirm the certification is current before specifying.
Yes, for small work. H100 is available in 10.5 ounce Hot Shot cartridges as well as 5-gallon pails, so a crew can address an active leak without setting up a full pump.
Water cutoff of large-flow and high-pressure leaks; foundation elements such as diaphragm walls, sheet piling, and secant piles; stabilization and cutoff of large cracks, voids, and gravel layers; pre and post injection in mines, tunnels, pipe jacking, drill and blast, and tunnel boring work; injection combined with cement-based grout; soil stabilization and anchors in porous geology; sewer sealing; probe grouting for below-grade pipes; and manhole injection.
A single-component airless injection pump is recommended, along with injection packers and valves, Alchatek Gen Cat or Gen Cat Fast, and a pump flush or cleaning solvent for shutdown. For small leaks the Hot Shot cartridge needs no pump.
Mostly expansion. Both are single-component hydrophobic semi-rigid resins that need a catalyst and do the same kinds of jobs. H100 expands 18 times; HighFoamer expands up to 50 times and works down to 34 degrees F rather than 41. Alchatek's guidance is to consider HighFoamer when large voids are involved.
Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.
No. They are the same product. Alchatek dropped PUR from the name, so older data sheets, labels, and purchase orders may still read Spetec PUR H100. The resin itself did not change.
Proof & Verification
H100-PB-01
Tom Miller Dam Gate Replacement Leak Sealing
Choosing between H100 and a higher-expansion resin, or writing a manhole grouting spec? Get the call right before the crew mobilizes.
For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.