Soil Stabilization & Settlement Control · Water Cut-Off Resin

AP Fill 720 Polyurethane Water Cut-Off Resin

A single-component resin that expands up to 49 times the moment it meets water, for choking off high-flow leaks and filling the voids they leave behind.

NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.

Water cut-off

Void filling

Up to 49x expansion

Seawall & bulkhead washout

What it is

A high-expansion resin for stopping water and filling the space it made

AP Fill 720 is a single-component, water-activated, hydrophobic, closed-cell polyurethane injection resin used to cut off high-flow water leaks, fill voids behind concrete structures, and stabilize soil that water has washed out. It reacts on contact with water and expands up to 49 times its liquid volume, which is what lets a small injected quantity fill a large void and choke the flow at the same time.

Cured, it is semi-rigid, closed cell, and water impermeable. Set time is adjustable from about 22 seconds to about 95 seconds with Alchatek Gen Cat or Gen Cat Fast.

Where it is used

What AP Fill 720 is used for

AP Fill 720 sits in the Soil Stabilization & Settlement Control solution family, and it is the resin Alchatek points at seawall and waterfront work where soil is washing out behind the wall.

  • Cutting off high-flow, high-pressure leaks

  • Cutting off underground water flows

  • Filling voids behind concrete structures

  • Seawall and bulkhead soil washout

  • Stabilizing and sealing large cracks and gravel layers

  • Sewer leak cut-off and sewer stabilization

  • Probe grouting for below-grade pipes

  • Mine, tunnel, pipe jacking and TBM injection

Choosing between this and a permeation grout, meaning a thinner resin that soaks into the spaces between soil grains and binds them together? Use AP Fill 720 when there is an open void and water moving through it. Use AP Soil 600 or AP Fill 700 when the ground itself is loose and needs binding in place rather than filling.

How it works

How AP Fill 720 chokes off moving water

AP Fill 720 is injected with accelerator into the void or the leak, reacts with the water already there, expands up to 49 times its liquid volume, and cures into a closed-cell foam that fills the space and blocks the flow. The water is not an obstacle to the cure. It is the trigger for it, which is why this resin works in the wet conditions that defeat products needing a dry substrate.

The crew's control is dosage and accelerator choice. More accelerator reacts faster, and warmer material reacts faster still, so a fast-moving leak gets Gen Cat Fast at a high dose to cure before the resin washes away, while a slower seep gets a longer window to travel and fill. Cured, the foam is water impermeable, so it does not reabsorb water when the flow returns.

Technical specifications

Published properties


Uncured resin

Property

Value

Method

Appearance

Brown liquid

TDS

Viscosity at 77°F (25°C)

215 cP (215 mPa·s)

ASTM D-4878

Liquid density

69.9 lb/ft³ (1.12 kg/dm³)

ASTM D-3505; liquid resin, not cured foam


Cured properties

Property

Value

Method

Compressive strength, with fine sand

1,803 psi, or 259,632 psf (12,400 kPa)

ASTM C-39

Tensile strength

43 psi, or 6,192 psf (296 kPa)

ASTM D-1623

Tensile elongation

3.80%

ASTM D-1623

Shrinkage

Negligible

ASTM D-1042 / D-756


Set time and expansion with Alchatek Gen Cat

Gen Cat dosage

At 41°F (5°C)

At 59°F (15°C)

At 77°F (25°C)

5%

18 to 95 sec, 40x

18 to 78 sec, 40x

14 to 55 sec, 49x

8%

15 to 60 sec, 42x

14 to 51 sec, 42x

10 to 43 sec, 49x

10%

15 to 48 sec, 42x

11 to 41 sec, 42x

8 to 35 sec, 49x


Set time and expansion with Alchatek Gen Cat Fast

Gen Cat Fast dosage

At 41°F (5°C)

At 59°F (15°C)

At 77°F (25°C)

5%

19 to 75 sec, 42x

14 to 57 sec, 45x

9 to 43 sec, 49x

8%

15 to 40 sec, 42x

10 to 35 sec, 45x

7 to 30 sec, 49x

10%

10 to 35 sec, 42x

8 to 28 sec, 45x

5 to 22 sec, 49x


Handling & certification

Property

Value

Method / Note

Composition

Single component plus accelerator; water activated, hydrophobic, closed cell, semi-rigid, solvent free and phthalate free

TDS / product page

Storage

50–80°F (10–26°C)

TDS

Shelf life

24 months, unopened, within storage range

TDS

Packaging

5-gallon pail, 50-gallon drum, and 250-gallon tote

Product page

Certification

NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water. The listing carries use restrictions on wetted surface area and minimum tank volume. See the certificate.

TDS and certified product listing

Each set time cell gives the start of the reaction, the end of the reaction, and the expansion at that dosage and temperature. 41, 59 and 77 degrees F are the temperatures the data sheet tested at, not an application temperature range; no application range is published for this resin. Compressive strength describes sand permeated with the resin, not the cured foam alone, and the density row is the liquid resin, not the cured foam. Source: AP Fill 720 Technical Data Sheet, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets, procedures, and certificates

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.

Compatible equipment & accessories

What you need to inject AP Fill 720

  • Single-component airless injection pump, recommended for AP Fill 720. View pumps 

  • Alchatek Gen Cat, the standard accelerator. Dosage from 5 to 10 percent sets the reaction. View accelerators 

  • Alchatek Gen Cat Fast, for conditions that need the reaction to finish sooner. View accelerators 

  • Alchatek Pump Flush, reusable, biodegradable pump flush. This resin can be set to finish reacting in about 22 seconds, so stage the flush before injecting. View flush 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Cutting off high-flow water and filling the void it leaves behind. Its published uses are filling voids behind concrete structures, cutting off high-flow leaks, cutting off underground water flows, stabilizing soil, and seawall repair.

Up to 49 times its liquid volume at 77 degrees F, and 40 to 45 times at 41 to 59 degrees F, per the published set time tables. Expansion rises with material temperature, so warmer resin fills more volume than colder resin at the same accelerator dosage.

As fast as 22 seconds end to end, and it is adjustable. The fastest published combination is Gen Cat Fast at 10 percent and 77 degrees F, which starts reacting in 5 seconds and finishes at 22. The slowest published combination is Gen Cat at 5 percent and 41 degrees F, which starts at 18 seconds and finishes at 95.

Speed, at the same dosage and temperature. At 10 percent and 59 degrees F, Gen Cat starts in 11 seconds and finishes at 41; Gen Cat Fast starts in 8 seconds and finishes at 28. Both are dosed from 5 to 10 percent and both reach the same expansion range. Choose by how fast the water is moving, then fine-tune with dosage.

Expansion and viscosity, which point them at two different jobs. AP Fill 720 is thicker at 215 cP and expands up to 49 times, so it fills volume and chokes off flow. AP Fill 700 is thinner at 120 cP and publishes no expansion figure, because its job is to travel between sand grains and bind them. Use 720 when there is a void and moving water; use 700 when the soil itself needs permeating.

Published compressive strength is 1,803 psi, or 259,632 psf, tested with fine sand by ASTM C-39. Tensile strength is 43 psi, or 6,192 psf, with 3.80 percent tensile elongation by ASTM D-1623, and shrinkage is negligible. The compressive figure describes resin-filled sand, not the foam on its own, so read it in that context.

Hydrophobic. It reacts with water to cure and then repels it, curing closed cell and water impermeable, so the cured foam does not reabsorb water. It is also solvent free and phthalate free.

Yes. Seawall repair is a published use, and this is the resin Alchatek points at soil washing out behind seawalls and bulkheads. It fills the void and cuts off the water moving through it. Pair it with a permeation grout when the surrounding soil also needs binding, and bring Technical Services in on the sequence.

AP Fill 720 is certified to NSF/ANSI/CAN 61, which covers contact with drinking water, and to NSF/ANSI/CAN 372, which covers lead content. The listing carries use restrictions on wetted surface area and minimum tank volume, so read the certificate and confirm the certification is current before specifying.

A single-component airless injection pump is recommended, with Alchatek Gen Cat or Gen Cat Fast as the accelerator and Alchatek Pump Flush for shutdown. Because this resin can be set to finish reacting in about 22 seconds, stage the flush before injecting rather than after.

5-gallon pails, 50-gallon drums, and 250-gallon totes.

Unopened containers have a 24 month shelf life when stored between 50 and 80 degrees F.

Proof & Verification

APFILL720-PB-01

Gravel Wall Stabilization

An old brick retaining wall in downtown Greenville collapsed and crushed three cars, requiring stabilization of the embankment and installation of a new wall system.
View case study

APFILL720-PB-02

Slot 2: Performance Data Point or Credential

empty, Alchatek to supply
Case Studies

APFILL720-PB-03

Slot 3: Documentation Reference

empty, Alchatek to supply
Case Studies

Water moving faster than you can fill the void behind it? Talk the flow, the temperature and the set time through before the pump goes out.

For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.