Concrete Leveling & Stabilization · Structural Foam
AP Lift 430 Structural Polyurethane Foam
A two component structural foam that lifts a settled slab back to grade and densifies the ground beneath it in the same pass, at roughly 90 percent of full strength in 15 minutes.
NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.
Slab Lifting & Leveling
Void Filling
Soil Densification
Traffic Ready Same Day
On this page:
What it is
A structural foam that lifts the slab and firms up what is under it
AP Lift 430 is a two component, high-expansion structural polyurethane foam used to raise settled concrete slabs, fill the voids beneath them, and densify and strengthen the weak ground that let them settle. It is a 3 lb foam, meaning a nominal cured density of 3 pounds per cubic foot, which is the grade contractors specify for residential and light commercial slab work.
The two sides are heated, metered, and mixed at the gun, then injected through small ports drilled in the slab.
Where it is used
What AP Lift 430 is used for
AP Lift 430 sits in the Concrete Leveling and Stabilization solution family, and is also used for soil stabilization work where the ground itself is the problem.
Lifting and leveling settled concrete slabs
Concrete slab foundation repair
Filling voids beneath slabs
Densifying and stabilizing weak soil
Fracture grouting
Filling abandoned pipes
Not sure whether the slab or the ground is the real problem? Start with settled concrete slabs if the concrete has dropped but the ground below is still solid, or soil instability beneath structures if the ground itself is weak or still moving.
How it works
How AP Lift 430 raises a slab in controlled increments
Small ports are drilled through the slab, the two components are heated and mixed at the gun, and the foam is injected beneath the concrete, where it expands in seconds, fills the void, compresses the surrounding soil, and then lifts the slab. Because the reaction is measured in seconds rather than minutes, a crew injects in short bursts and watches the slab move, rather than committing a large volume and hoping.
If that window is too long for your conditions, AP Lift 430 Fast is the same 3 lb foam with a shorter one. The two are compared side by side in the specifications below.
Cure follows almost immediately. The data sheet publishes 90 percent of full strength in about 15 minutes, which is why slab lifting is typically a same-day return to service instead of a multi-day closure. Confirm return to service for your loading and site conditions before scheduling traffic.
Technical specifications
Published properties
Cured foam
Property | Value | Method |
|---|---|---|
Density, free rise | 3 lb foam. Nominal 3 lb/ft³, range 2.75 to 3.25 lb/ft³ (44 to 52 kg/m³) | ASTM D1622 |
Compressive strength, free rise | 50 psi, or 7,200 psf (345 kPa) | TDS |
Tensile strength, free rise | 88 psi, or 12,700 psf (607 kPa) | TDS |
Flexural strength | 90 psi (621 kPa) | TDS |
Closed cell content | 92% | TDS |
Water absorption | Less than 8% | TDS |
Expansion, unconfined | Up to 25 times liquid volume | TDS |
Strength development | 90% of full strength in about 15 minutes | TDS |
Reaction profile at 105°F, standard compared with Fast
Stage | AP Lift 430 | AP Lift 430 Fast | Method |
|---|---|---|---|
Cream time | 2 seconds | 2 seconds | ASTM D7487 |
Tack-free time | 17 seconds | 11 seconds | ASTM D7487 |
Rise time | 23 seconds | 18 seconds | ASTM D7487 |
Everything else is the same: both are 3 lb foams at 50 psi free-rise compressive strength, 92 percent closed cell, 25 times unconfined expansion, 15 minutes to 90 percent of full strength. Only the reaction window differs. AP Lift 430 Fast is the choice in cold, wet, or harsh conditions where the standard product would travel too far before it sets.
Liquid components
Property | A side | B side |
|---|---|---|
Specific gravity | 1.23 | 1.03 |
Weight per gallon | 10.25 lb | 8.6 lb |
Viscosity at 110°F | 200 cP (200 mPa·s) | |
Mix ratio | 1:1 by volume, per the certified product listing | |
Equipment settings, not ambient air temperature
Setting | Temperature | Note |
|---|---|---|
A-side material heater | 100°F (38°C) | Machine setting |
B-side material heater | 110°F (43°C) | Machine setting |
Hose | 105°F (41°C) | Machine setting |
Handling & certification
Property | Value | Method / Note |
|---|---|---|
Composition | Two component structural polyurethane foam, heated and mixed at the gun | TDS |
Packaging | 100-gallon and 500-gallon units, each a matched A-side and B-side pair | Product page |
Shelf life | 24 months in unopened containers stored within the range above | TDS |
Certification | NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water, with limits on wetted surface area, minimum tank volume, dry film thickness, and cure time before contact; not intended for pipe application. Read the certificate for the conditions of the listing. | TDS Rev. 1/20/2026 and certified product listing |
AP Lift 430 is a 3 lb foam. Density is how these foams are graded, so a 3 lb, a 4 lb and a 6 lb foam are different products for different loads, and the range above is the manufacturing tolerance on that grade, not a choice. Compressive, tensile, and density values are free-rise laboratory figures. Confined beneath a slab the foam reaches a higher density and higher strength than the free-rise numbers above. Expansion is 25 times unconfined. Temperatures in the equipment table are material temperatures at the machine, not air temperature limits for the job site. Source: AP Lift 430 Technical Data Sheet, Rev. 1/20/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.
Downloads
Data sheets, specifications, procedures, and certificates
Technical Data Sheet (TDS)
Published properties · PDF
Safety Data Sheet, Part A
AP 400 Series A side · PDF
Safety Data Sheet, Part B
AP Lift 430 B side · PDF
Specification, CSI 31 43 00
Concrete raising · PDF
Procedures, Slab Lift Process
Field procedure · PDF
Procedures, Deep Lock® Process
Field procedure · PDF
NSF/ANSI/CAN 61 & 372 Certificate
Certified product listing · PDF
Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.
Compatible equipment & accessories
What you need to install AP Lift 430
Two-component proportioner with material heaters, required. AP Lift 430 cannot be poured or hand mixed. View proportioners
MixMaster Pro slab lifting gun, the standard gun for slab work. View gun
PX-7 slab lifting gun, the alternate gun option. View gun
3/8 inch hammer-in injection ports, named in the CSI 31 43 00 specification. View ports
Alchatek Surface Guard 125, protects finished surfaces during injection. View accessory
Alchatek Pump Flush, reusable, biodegradable pump flush for shutdown. View flush
Alchatek Soak 130, cured-polyurethane cleaning solvent. View solvent
Related articles & guides
Learn the method behind the product
Concrete Leveling with AP 430, 440 and 475
Product comparison
Polyurethane Slab Lifting Explained
Method explainer
Concrete Leveling with Polyurethane Foam - How Strong is Strong Enough?
Strength benchmarks
Frequently Asked Questions
Lifting and leveling settled concrete slabs, filling the voids beneath them, stabilizing the soil that let them settle, and fracture grouting. It is the residential and light commercial member of the AP Lift line.
Both. The foam expands into voids and weak ground beneath the slab, compresses and densifies that soil as it expands, then cures into a closed-cell structural mass that carries load. Lifting the slab without addressing the ground beneath it is what lets a slab settle again.
The technical data sheet publishes an unconfined expansion of up to 25 times its liquid volume. Unconfined is a laboratory free-rise figure. Under a slab the foam is confined, so real expansion is lower and the resulting density is higher.
The data sheet publishes 90 percent of full strength in about 15 minutes, which is why slab lifting is generally described as same-day work rather than a multi-day cure. Confirm return to service for your loading and conditions with Technical Services.
It is a 3 lb foam. Published free-rise values are 50 psi compressive strength, or 7,200 psf, and 88 psi tensile strength, or 12,700 psf, at that nominal cured density of 3 pounds per cubic foot. Flexural strength is 90 psi and the foam is 92 percent closed cell.
A two-component proportioner with material heaters, plus a slab lifting gun, either the MixMaster Pro or the PX-7. This is not a product that can be poured or hand mixed. The two sides are heated, metered, and mixed at the gun.
The reaction is temperature dependent. The data sheet gives equipment settings of 100 degrees F on the A side, 110 degrees F on the B side, and 105 degrees F at the hose. Those are material temperatures at the machine, not air temperature limits for the job site.
At the published 105 degree F test temperature, cream time is 2 seconds, tack-free time is 17 seconds, and rise time is 23 seconds, by ASTM D7487. The reaction is measured in seconds, which is what allows a crew to lift in controlled increments and watch the slab. AP Lift 430 Fast runs the same test at 2 seconds cream, 11 seconds tack-free, and 18 seconds rise.
AP Lift 430 is certified to NSF/ANSI/CAN 61 and 372. The listing carries conditions, including limits on wetted surface area, a minimum tank volume, a maximum dry film thickness, and a cure period before contact, and it is not intended for pipe application. Read the certificate for the full conditions and confirm the listing is current before specifying.
Yes. Alchatek publishes a CSI Section 31 43 00 specification, Concrete Raising, written around AP Lift 430 and its accessories. It is in the downloads on this page, along with the slab lifting and Deep Lock procedures.
100-gallon and 500-gallon units. Each unit is a matched pair of A-side and B-side containers.
The reaction window, and nothing else that matters structurally. Both are 3 lb foams with the same 50 psi free-rise compressive strength, 92 percent closed cell content, 25 times unconfined expansion, and 15 minutes to 90 percent of full strength. AP Lift 430 Fast reaches tack-free in 11 seconds against 17, and completes its rise in 18 seconds against 23. Choose Fast when conditions are cold, wet, or otherwise harsh and the standard product would travel too far before it sets.
Confirm shelf life and storage conditions against the current technical data sheet before ordering. Both sides should be kept sealed and within the storage range on the sheet.
Proof & Verification
APLIFT430-PB-01
Leveling Sunken Slabs in a Pole Barn
APLIFT430-PB-02
Slot 2: Performance Data Point or Credential
APLIFT430-PB-03
Slot 3: Documentation Reference
Slab dropped, void underneath, and ground you are not sure about? Talk the lift and the soil through together before the ports go in.
For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.