Soil Stabilization & Settlement Control · Deep Injection Foam
AP Deep Lift® 420 High-Expansion Polyurethane Foam
A 2 lb foam that expands up to 35 times its liquid volume, injected through tubes driven to depth. It treats the ground below a structure rather than the void directly under a slab.
ISO 9001 Certified · Facility-wide quality management certification.
Lifting structures from depth
Deep Lock® process
Void filling
Flotation foam
On this page:
What it is
A deep injection foam, placed below the structure rather than under the slab
AP Deep Lift® 420 is a two component, high-expansion, hydro-insensitive polyurethane foam used to lift structures from deep beneath the soil, fill voids, and serve as flotation foam. It is a 2 lb foam that expands up to 35 times its liquid volume and reaches tack free in 13 seconds. It is placed through injection tubes driven to a chosen depth, under Alchatek's Deep Lock® process, rather than through ports drilled in concrete.
It is hydro insensitive, which means water does not stop the reaction, and the product page states that the foam displaces water as it expands. The two sides are heated, metered, and mixed at the gun.
Where it is used
What AP Deep Lift 420 is used for
AP Deep Lift® 420 sits in the Soil Stabilization and Settlement Control solution family, where the problem is the ground rather than the concrete on top of it. The data sheet lists these uses:
Lifting structures from deep beneath the soil
Filling voids
Flotation foam
Not sure whether the ground or the slab is the real problem? Start with soil instability beneath structures if the ground itself is weak or still moving, or settled concrete slabs if the concrete has dropped but the ground below is still solid. If material is washing out from under a structure, start with soil erosion and washout.
How it works
How the Deep Lock® process places foam at depth
Injection tubes are driven to a chosen depth, the two components are heated and mixed at the gun, and the foam is injected into the soil profile below the structure, where it expands, displaces water, and cures into a closed-cell mass bonded to the surrounding ground. Alchatek publishes the Deep Lock® process procedure covering the proportioners, tube sizes and tips, ground rod drivers and testing equipment the method calls for. It is in the downloads below.
The reaction is fast by design. Cream time is 1 second and tack free is 13 seconds at the published 105 degree F test temperature, which is roughly three times faster to tack free than AP Fill 420, a foam with otherwise identical published properties. A short window keeps material where the tube places it instead of letting it migrate through open ground.
Strength develops quickly. The data sheet publishes 90 percent of full strength in about 15 minutes. Because a deep lift depends on the soil profile, the structure, and what is being measured at the surface, treat the design as an engineering exercise and involve Technical Services early.
Technical specifications
Published properties
Cured foam, free rise
Property | Value | Method |
|---|---|---|
Density, free rise | 2 lb foam. Nominal 2 lb/ft³, range 1.75 to 2.25 lb/ft³ (28 to 36 kg/m³) | ASTM D1622 |
Compressive strength, free rise | 22 psi, or 3,170 psf (152 kPa) | ASTM D1621 / D1622 |
Shear strength, free rise | 11 psi, or 1,580 psf (76 kPa) | ASTM C273 |
Flexural strength | 50 psi, or 7,200 psf (345 kPa) | ASTM D790 |
Shrinkage | Negligible | ASTM D1042 / D756 |
Expansion, unconfined | Up to 35 times liquid volume | TDS |
Strength development | 90% of full strength in about 15 minutes | TDS |
NY-Panel result | Pass, 93.70% density retention | TDS |
Cured foam, confined
Property | 1.5x | 2x | 3x |
|---|---|---|---|
Compressive strength, confined | 40 psi, 5,760 psf | 60 psi, 8,640 psf | 98 psi, 14,100 psf |
Shear strength, confined | 20 psi, 2,880 psf | 30 psi, 4,320 psf | 49 psi, 7,060 psf |
Confined values are what the foam does once it is compacted in soil rather than rising freely, which is why they run above the free-rise figures. The data sheet labels these levels 1.5x, 2x and 3x without stating what the multiplier is measured against, so confirm the basis with Technical Services before using them in a submittal.
Reaction profile at 105°F
Stage | Time | Method |
|---|---|---|
Cream time | 1 second | ASTM D7487 |
Tack-free time | 13 seconds | ASTM D7487 |
Rise time | 15 seconds | ASTM D7487 |
Liquid components
Property | A side | B side |
|---|---|---|
Specific gravity | 1.23 | 1.02 |
Weight per gallon | 10.25 lb | 8.5 lb |
Viscosity at 110°F | 200 cP (200 mPa·s), ASTM D4878 | |
Equipment settings, not ambient air temperature
Setting | Temperature | Note |
|---|---|---|
A-side material heater | 100°F (38°C) | Machine setting |
B-side material heater | 110°F (43°C) | Machine setting |
Hose | 105°F (41°C) | Machine setting |
Handling and storage
Property | Value | Method / Note |
|---|---|---|
Composition | Two component high-expansion polyurethane foam, heated and mixed at the gun | TDS |
Storage temperature | 50 to 80°F (10 to 26°C) | TDS |
Shelf life | 24 months in unopened containers stored within the range above | TDS |
Packaging | 100-gallon and 500-gallon units, each a matched A-side and B-side pair | Product page |
AP Deep Lift 420 is a 2 lb foam. Density is how these foams are graded, and the range above is the manufacturing tolerance on that grade, not a choice. Free-rise values are unconfined laboratory figures; confined in soil the foam reaches a higher density and higher strength, which is what the confined table shows. This data sheet publishes no tensile strength, no mix ratio, no closed cell percentage and no water absorption, and none of those has been carried across from another product's data sheet. Temperatures in the equipment table are material temperatures at the machine, not air temperature limits for the job site, and no ambient application range is published for this product. Source: AP Deep Lift 420 Technical Data Sheet, Rev. 1/20/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.
Downloads
Data sheets and procedures
Technical Data Sheet (TDS)
Published properties · PDF
Safety Data Sheet, Part A
AP 400 Series A side · PDF
Safety Data Sheet, Part B
AP Deep Lift 420 B side · PDF
Procedures, Deep Lock® Process
Field procedure · PDF
Deep Lock® Brochure
Request the brochure · Short form
Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library. For a specification naming AP Deep Lift 420, contact Technical Services.
Compatible equipment & accessories
What you need to install AP Deep Lift 420
Two-component proportioner with material heaters, required. AP Deep Lift 420 cannot be poured or hand mixed. View proportioners
Injection tubing, 5/8 inch and 1/2 inch outside diameter, with pointed tube tips, named in the Deep Lock® process procedure. View tubing
Ground rod driving equipment, for driving tube to depth. Specific models are named in the Deep Lock® process procedure.
Soil testing and utility location, a dynamic cone penetrometer and ground penetrating radar, both called for in the procedure before injection begins.
Alchatek Pump Flush, reusable, biodegradable pump flush for shutdown. View flush
Alchatek Soak 130, cured-polyurethane cleaning solvent. View solvent
Related articles & guides
Learn the method behind the product
Deep Lock® with Polyurethane
Method explainer
Lifting Foam Density and Expansion
Grade selection
Concrete Leveling with Polyurethane Foam - How Strong is Strong Enough?
Strength benchmarks
The Deep Lift® Process Explained
Method explainer
Frequently Asked Questions
Lifting structures from deep beneath the soil, filling voids, and serving as flotation foam. Those are the three uses on its data sheet, in that order. It is placed at depth through injection tubes rather than through ports drilled in a slab.
The reaction speed and the intended application. Every published cured property is identical: both are 2 lb foams at 22 psi free-rise compressive strength, 11 psi shear, 50 psi flexural, 35 times unconfined expansion, and the same confined values. What differs is the reaction. AP Deep Lift 420 creams in 1 second and is tack free in 13; AP Fill 420 creams in 5 seconds and is tack free in 36. They also carry different B-side part numbers, so they are separate products rather than one product under two names. AP Deep Lift 420 is for lifting structures from depth; AP Fill 420 is for filling voids, abandoned pipes and mine shafts.
By how it is placed rather than by raw strength. The data sheet lists lifting structures from deep beneath the soil as its first use, and Alchatek publishes the Deep Lock process procedure for injecting it through tubes driven to depth rather than through ports in a slab. It is a 2 lb foam at 22 psi free-rise compressive strength, so it is not a slab jacking product. A deep lift is an engineered operation that depends on the soil profile and the structure, so bring Technical Services in at the design stage.
It is Alchatek's published method for injecting structural polymer at a chosen depth through tubes or pipes, to stabilize weak subgrade rather than only the void directly under a slab. The field procedure is in the downloads on this page, along with the Deep Lock brochure. The procedure names the proportioners, tube sizes, tips, ground rod drivers and testing equipment the method calls for.
The technical data sheet publishes an unconfined expansion of 35 times its liquid volume, the highest Alchatek publishes in this range. Unconfined is a laboratory free-rise figure. Injected into soil the foam is confined, so real expansion is lower and the resulting density is higher.
It is a 2 lb foam. Published free-rise values are 22 psi compressive strength, or 3,170 psf, and 11 psi shear strength, or 1,580 psf, at a nominal cured density of 2 pounds per cubic foot. Flexural strength is 50 psi. Confined in soil the foam reaches a higher density and higher strength than these free-rise figures, and the data sheet publishes confined values at three levels of confinement.
They are compressive and shear values measured at three levels of confinement, labelled 1.5x, 2x and 3x on the data sheet, running from 40 psi compressive at 1.5x up to 98 psi at 3x. The data sheet does not define what the multiplier is measured against, so confirm the basis with Technical Services before using these values in a submittal.
It is hydro insensitive, which means water does not stop the reaction, and the product page states that it displaces water as it expands. Confirm the approach for your specific ground conditions with Technical Services, particularly where the soil is saturated or water is moving through it.
A two-component proportioner with material heaters, plus injection tubing and the driving equipment the Deep Lock process procedure specifies. This is not a product that can be poured or hand mixed. The two sides are heated, metered, and mixed at the gun.
The reaction is temperature dependent. The data sheet gives equipment settings of 100 degrees F on the A side, 110 degrees F on the B side, and 105 degrees F at the hose. Those are material temperatures at the machine, not air temperature limits for the job site.
The data sheet publishes a shelf life of 24 months in unopened containers stored between 50 and 80 degrees F. Both sides should be kept sealed and within that range.
No. AP Deep Lift 420 carries no NSF certification. Its data sheet makes no certification claim and no certificate is published for it. Where a job requires contact with drinking water, use a product that carries a current certificate and read that certificate for the conditions of its listing.
100-gallon and 500-gallon units. Each unit is a matched pair of A-side and B-side containers.
Proof & Verification
APDEEPLIFT420-PB-01
Slot 1: Named Project / Case Study
APDEEPLIFT420-PB-02
Slot 2: Performance Data Point / Credential
APDEEPLIFT420-PB-03
Slot 3: Documentation Reference
Structure settling because the ground under it is weak, not because a slab dropped? Talk the soil profile and the injection depth through before anything is driven.
For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.