Soil Stabilization & Settlement Control · Deep Injection Foam

AP Deep Lift® 420 High-Expansion Polyurethane Foam

A 2 lb foam that expands up to 35 times its liquid volume, injected through tubes driven to depth. It treats the ground below a structure rather than the void directly under a slab.

ISO 9001 Certified · Facility-wide quality management certification.

Lifting structures from depth

Deep Lock® process

Void filling

Flotation foam

What it is

A deep injection foam, placed below the structure rather than under the slab

AP Deep Lift® 420 is a two component, high-expansion, hydro-insensitive polyurethane foam used to lift structures from deep beneath the soil, fill voids, and serve as flotation foam. It is a 2 lb foam that expands up to 35 times its liquid volume and reaches tack free in 13 seconds. It is placed through injection tubes driven to a chosen depth, under Alchatek's Deep Lock® process, rather than through ports drilled in concrete.

The word Lift here means lifting from depth, not slab jacking

At 22 psi free-rise compressive strength this is the lightest grade Alchatek publishes, and it is not a slab jacking foam injected through ports in a driveway or a warehouse floor. For that, the AP Lift grades start at 3 lb and 50 psi. AP Deep Lift® 420 does its work in the soil profile, and a deep lift is an engineered operation rather than a product choice.

It is hydro insensitive, which means water does not stop the reaction, and the product page states that the foam displaces water as it expands. The two sides are heated, metered, and mixed at the gun.

Where it is used

What AP Deep Lift 420 is used for

AP Deep Lift® 420 sits in the Soil Stabilization and Settlement Control solution family, where the problem is the ground rather than the concrete on top of it. The data sheet lists these uses:

  • Lifting structures from deep beneath the soil

  • Filling voids

  • Flotation foam

Not sure whether the ground or the slab is the real problem? Start with soil instability beneath structures if the ground itself is weak or still moving, or settled concrete slabs if the concrete has dropped but the ground below is still solid. If material is washing out from under a structure, start with soil erosion and washout.

How it works

How the Deep Lock® process places foam at depth

Injection tubes are driven to a chosen depth, the two components are heated and mixed at the gun, and the foam is injected into the soil profile below the structure, where it expands, displaces water, and cures into a closed-cell mass bonded to the surrounding ground. Alchatek publishes the Deep Lock® process procedure covering the proportioners, tube sizes and tips, ground rod drivers and testing equipment the method calls for. It is in the downloads below.

The reaction is fast by design. Cream time is 1 second and tack free is 13 seconds at the published 105 degree F test temperature, which is roughly three times faster to tack free than AP Fill 420, a foam with otherwise identical published properties. A short window keeps material where the tube places it instead of letting it migrate through open ground.

Strength develops quickly. The data sheet publishes 90 percent of full strength in about 15 minutes. Because a deep lift depends on the soil profile, the structure, and what is being measured at the surface, treat the design as an engineering exercise and involve Technical Services early.

Bar chart of AP Lift foam expansion rates and strength, from AP 420 at 35x and 22 psi to AP 460 at 12x and 125 psi

Technical specifications

Published properties


Cured foam, free rise

Property

Value

Method

Density, free rise

2 lb foam. Nominal 2 lb/ft³, range 1.75 to 2.25 lb/ft³ (28 to 36 kg/m³)

ASTM D1622

Compressive strength, free rise

22 psi, or 3,170 psf (152 kPa)

ASTM D1621 / D1622

Shear strength, free rise

11 psi, or 1,580 psf (76 kPa)

ASTM C273

Flexural strength

50 psi, or 7,200 psf (345 kPa)

ASTM D790

Shrinkage

Negligible

ASTM D1042 / D756

Expansion, unconfined

Up to 35 times liquid volume

TDS

Strength development

90% of full strength in about 15 minutes

TDS

NY-Panel result

Pass, 93.70% density retention

TDS




Cured foam, confined

Property

1.5x

2x

3x

Compressive strength, confined

40 psi, 5,760 psf

60 psi, 8,640 psf

98 psi, 14,100 psf

Shear strength, confined

20 psi, 2,880 psf

30 psi, 4,320 psf

49 psi, 7,060 psf


Confined values are what the foam does once it is compacted in soil rather than rising freely, which is why they run above the free-rise figures. The data sheet labels these levels 1.5x, 2x and 3x without stating what the multiplier is measured against, so confirm the basis with Technical Services before using them in a submittal.


Reaction profile at 105°F

Stage

Time

Method

Cream time

1 second

ASTM D7487

Tack-free time

13 seconds

ASTM D7487

Rise time

15 seconds

ASTM D7487


Liquid components

Property

A side

B side

Specific gravity

1.23

1.02

Weight per gallon

10.25 lb

8.5 lb

Viscosity at 110°F

200 cP (200 mPa·s), ASTM D4878


Equipment settings, not ambient air temperature

Setting

Temperature

Note

A-side material heater

100°F (38°C)

Machine setting

B-side material heater

110°F (43°C)

Machine setting

Hose

105°F (41°C)

Machine setting


Handling and storage

Property

Value

Method / Note

Composition

Two component high-expansion polyurethane foam, heated and mixed at the gun

TDS

Storage temperature

50 to 80°F (10 to 26°C)

TDS

Shelf life

24 months in unopened containers stored within the range above

TDS

Packaging

100-gallon and 500-gallon units, each a matched A-side and B-side pair

Product page

AP Deep Lift 420 is a 2 lb foam. Density is how these foams are graded, and the range above is the manufacturing tolerance on that grade, not a choice. Free-rise values are unconfined laboratory figures; confined in soil the foam reaches a higher density and higher strength, which is what the confined table shows. This data sheet publishes no tensile strength, no mix ratio, no closed cell percentage and no water absorption, and none of those has been carried across from another product's data sheet. Temperatures in the equipment table are material temperatures at the machine, not air temperature limits for the job site, and no ambient application range is published for this product. Source: AP Deep Lift 420 Technical Data Sheet, Rev. 1/20/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets and procedures

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library. For a specification naming AP Deep Lift 420, contact Technical Services.

Compatible equipment & accessories

What you need to install AP Deep Lift 420

  • Two-component proportioner with material heaters, required. AP Deep Lift 420 cannot be poured or hand mixed. View proportioners 

  • Injection tubing, 5/8 inch and 1/2 inch outside diameter, with pointed tube tips, named in the Deep Lock® process procedure. View tubing 

  • Ground rod driving equipment, for driving tube to depth. Specific models are named in the Deep Lock® process procedure.

  • Soil testing and utility location, a dynamic cone penetrometer and ground penetrating radar, both called for in the procedure before injection begins.

  • Alchatek Pump Flush, reusable, biodegradable pump flush for shutdown. View flush 

  • Alchatek Soak 130, cured-polyurethane cleaning solvent. View solvent 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Lifting structures from deep beneath the soil, filling voids, and serving as flotation foam. Those are the three uses on its data sheet, in that order. It is placed at depth through injection tubes rather than through ports drilled in a slab.

The reaction speed and the intended application. Every published cured property is identical: both are 2 lb foams at 22 psi free-rise compressive strength, 11 psi shear, 50 psi flexural, 35 times unconfined expansion, and the same confined values. What differs is the reaction. AP Deep Lift 420 creams in 1 second and is tack free in 13; AP Fill 420 creams in 5 seconds and is tack free in 36. They also carry different B-side part numbers, so they are separate products rather than one product under two names. AP Deep Lift 420 is for lifting structures from depth; AP Fill 420 is for filling voids, abandoned pipes and mine shafts.

By how it is placed rather than by raw strength. The data sheet lists lifting structures from deep beneath the soil as its first use, and Alchatek publishes the Deep Lock process procedure for injecting it through tubes driven to depth rather than through ports in a slab. It is a 2 lb foam at 22 psi free-rise compressive strength, so it is not a slab jacking product. A deep lift is an engineered operation that depends on the soil profile and the structure, so bring Technical Services in at the design stage.

It is Alchatek's published method for injecting structural polymer at a chosen depth through tubes or pipes, to stabilize weak subgrade rather than only the void directly under a slab. The field procedure is in the downloads on this page, along with the Deep Lock brochure. The procedure names the proportioners, tube sizes, tips, ground rod drivers and testing equipment the method calls for.

The technical data sheet publishes an unconfined expansion of 35 times its liquid volume, the highest Alchatek publishes in this range. Unconfined is a laboratory free-rise figure. Injected into soil the foam is confined, so real expansion is lower and the resulting density is higher.

It is a 2 lb foam. Published free-rise values are 22 psi compressive strength, or 3,170 psf, and 11 psi shear strength, or 1,580 psf, at a nominal cured density of 2 pounds per cubic foot. Flexural strength is 50 psi. Confined in soil the foam reaches a higher density and higher strength than these free-rise figures, and the data sheet publishes confined values at three levels of confinement.

They are compressive and shear values measured at three levels of confinement, labelled 1.5x, 2x and 3x on the data sheet, running from 40 psi compressive at 1.5x up to 98 psi at 3x. The data sheet does not define what the multiplier is measured against, so confirm the basis with Technical Services before using these values in a submittal.

It is hydro insensitive, which means water does not stop the reaction, and the product page states that it displaces water as it expands. Confirm the approach for your specific ground conditions with Technical Services, particularly where the soil is saturated or water is moving through it.

A two-component proportioner with material heaters, plus injection tubing and the driving equipment the Deep Lock process procedure specifies. This is not a product that can be poured or hand mixed. The two sides are heated, metered, and mixed at the gun.

The reaction is temperature dependent. The data sheet gives equipment settings of 100 degrees F on the A side, 110 degrees F on the B side, and 105 degrees F at the hose. Those are material temperatures at the machine, not air temperature limits for the job site.

The data sheet publishes a shelf life of 24 months in unopened containers stored between 50 and 80 degrees F. Both sides should be kept sealed and within that range.

No. AP Deep Lift 420 carries no NSF certification. Its data sheet makes no certification claim and no certificate is published for it. Where a job requires contact with drinking water, use a product that carries a current certificate and read that certificate for the conditions of its listing.

100-gallon and 500-gallon units. Each unit is a matched pair of A-side and B-side containers.

Proof & Verification

APDEEPLIFT420-PB-01

Slot 1: Named Project / Case Study

Project name · asset class & location · condition addressed · method & system family · documented outcome · documentation reference (Downloads).
Case Studies

APDEEPLIFT420-PB-02

Slot 2: Performance Data Point / Credential

Claim · supporting evidence · source · date.
Case Studies

APDEEPLIFT420-PB-03

Slot 3: Documentation Reference

Link to the full case study / formal file in Downloads. Leave empty until the real reference exists.
Case Studies

Structure settling because the ground under it is weak, not because a slab dropped? Talk the soil profile and the injection depth through before anything is driven.

For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.