AP Lift 475 Structural Polyurethane Foam

The 4.75 lb grade, at 110 psi free-rise compressive strength. Specified for heavy, intensive work, and it is the grade written into the deep injection specification, where material is placed through tubes rather than through the slab.

NSF/ANSI/CAN 61 & 372 Certified · Certified for contact with drinking water. The listing carries use restrictions.

Heavy & intensive applications

Deep Lock® injection

Void & annular space fill

Soil densification

What it is

The 4.75 lb grade, and the one specified for deep injection

AP Lift 475 is a two component structural polyurethane foam used to stabilize soil, lift concrete slabs, and fill voids and annular spaces under heavy loads. It is a 4.75 lb foam, meaning a nominal cured density of 4.75 pounds per cubic foot, at 110 psi free-rise compressive strength. Density is the whole basis on which these products are selected, and the grades are not interchangeable: 475 carries more load than the 4 lb 440 and less than AP Lift 460.

What separates it from the rest of the line is not only the grade. AP Lift 475 is the product written into Alchatek's deep injection specification, where the foam goes in through tubes or pipes driven to depth rather than through ports drilled in a slab. That makes it the grade for treating weak ground below a structure, not just the void directly beneath it. It is also hydro insensitive, so water in the ground does not stop the reaction.

Where it is used

What AP Lift 475 is used for

AP Lift 475 sits in the Concrete Leveling and Stabilization solution family, and is heavily used for soil stabilization work, including deep injection through tubes under the Deep Lock® method. The data sheet lists these uses:

  • Stabilizing soil

  • Lifting concrete slabs

  • Filling voids and annular spaces

  • Supplemental sinkhole remediation

The product page adds compaction grouting, fracture grouting, and wet compaction grouting and void filling. Alchatek also publishes a technical document on stabilizing loose railroad ballast stone with AP Lift 475, in the downloads below.

Not sure whether the slab or the ground is the real problem? Start with settled concrete slabs if the concrete has dropped but the ground below is still solid, or soil instability beneath structures if the ground itself is weak or still moving. For settlement at a bridge approach, start with bridge approach settlement.

How it works

How AP Lift 475 treats the ground at depth, not just the void

Injected under a slab, the foam expands in seconds, fills the void, compresses the surrounding soil, and lifts the concrete. Injected through tubes driven to depth, the same foam permeates and compacts weak soil where it sits, building strength below a structure rather than only beneath the slab. Which of the two a job needs is a design decision, and it is the reason this grade has its own specification.

The heavier grade changes what a crew plans for. AP Lift 475 expands 15 times rather than the 18 of the 4 lb grade or the 25 of the 3 lb grades, so the same void takes noticeably more material and quantities must be taken from the 4.75 lb figures. Its reaction also runs a little differently, creaming in 4 seconds and reaching full rise at 27.

Cure follows almost immediately. The data sheet publishes 90 percent of full strength in about 15 minutes. Confirm return to service for your loading and site conditions before scheduling traffic.

Technical specifications

Published properties


Cured foam, free rise

Property

Value

Method

Density, free rise

4.75 lb foam. Nominal 4.75 lb/ft³, range 4.5 to 5.0 lb/ft³ (72 to 80 kg/m³)

ASTM D1622

Compressive strength, free rise

110 psi, or 15,800 psf (758 kPa)

ASTM D1621 / D1622

Tensile strength, free rise

100 psi, or 14,400 psf (689 kPa)

ASTM D638

Shear strength, free rise

55 psi, or 7,920 psf (379 kPa)

ASTM C273

Flexural strength

165 psi, or 23,800 psf (1,138 kPa)

ASTM D790

Closed cell content

91.3%

ASTM D6226

Shrinkage

Negligible

ASTM D1042 / D756

Dimensional change, thermal and humid aging

1 percent, 0.25 percent volume

ASTM D2126

Expansion, unconfined

15 times liquid volume

TDS

Strength development

90% of full strength in about 15 minutes

TDS

NY-Panel result

Pass, 95.8% density retention

TDS




Cured foam, confined

Property

1.5x

2x

3x

Compressive strength, confined

171 psi, 24,600 psf

252 psi, 36,300 psf

406 psi, 58,500 psf

Shear strength, confined

81 psi, 11,700 psf

126 psi, 18,100 psf

203 psi, 29,200 psf


Confined values are what the foam does once it is compacted against soil and a structure, which is why they run well above the free-rise figures. The data sheet labels these levels 1.5x, 2x and 3x without stating what the multiplier is measured against, so confirm the basis with Technical Services before using them in a submittal.


Reaction profile at 105°F

Stage

Time

Method

Cream time

4 seconds

ASTM D7487

Tack-free time

25 seconds

ASTM D7487

Rise time

27 seconds

ASTM D7487


Liquid components

Property

A side

B side

Specific gravity

1.23

1.04

Weight per gallon

10.25 lb

8.63 lb

Viscosity at 110°F

200 cP (200 mPa·s), ASTM D4878

Mix ratio

1:1. Not published on the data sheet; stated in the Alchatek railroad ballast technical document


Equipment settings, not ambient air temperature

Setting

Temperature

Note

A-side material heater

100°F (38°C)

Machine setting

B-side material heater

110°F (43°C)

Machine setting

Hose

105°F (41°C)

Machine setting


Handling & certification

Property

Value

Method / Note

Composition

Two component structural polyurethane foam, heated and mixed at the gun

TDS

Storage temperature

50 to 80°F (10 to 26°C)

TDS

Shelf life

24 months in unopened containers stored within the range above

TDS

Packaging

500-gallon unit, a matched A-side and B-side pair

Product page

Certification

NSF/ANSI/CAN 61 and 372. Certified for contact with drinking water, with a limit on how much of the total surface area may contact water, a minimum tank size, a maximum surface-area-to-volume ratio, and not intended for pipe application. Read the certificate for the conditions of the listing.

Certified product listing

AP Lift 475 is a 4.75 lb foam. Density is how these foams are graded, so a 3 lb, a 4 lb and a 4.75 lb foam are different products for different loads, and the range above is the manufacturing tolerance on that grade, not a choice. Free-rise values are unconfined laboratory figures; confined against soil and a structure the foam reaches a higher density and higher strength, which is what the confined table shows. Temperatures in the equipment table are material temperatures at the machine, not air temperature limits for the job site, and no ambient application range is published for this product. Source: AP Lift 475 Technical Data Sheet, Rev. 1/20/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.

Downloads

Data sheets, specifications, procedures, and certificates

Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library.

Compatible equipment & accessories

What you need to install AP Lift 475

  • Two-component proportioner with material heaters, required. AP Lift 475 cannot be poured or hand mixed. View proportioners 

  • MixMaster Pro slab lifting gun, the gun named in the specification for slab work. View gun 

  • PX-7 slab lifting gun, the alternate gun option. View gun 

  • 1/2 inch outside diameter injection tubing and 3/8 inch NPT pipe, for deep injection, named in CSI 02 55 00.

  • Alchatek Surface Guard 125, protects finished surfaces during injection. View accessory 

  • Alchatek Pump Flush, reusable, biodegradable pump flush for shutdown. View flush 

  • Alchatek Soak 130, cured-polyurethane cleaning solvent. View solvent 

Related articles & guides

Learn the method behind the product

Frequently Asked Questions

Stabilizing soil, lifting concrete slabs, filling voids and annular spaces, and supplemental sinkhole remediation. It is the heavy, intensive grade of the AP Lift line, and it is the grade written into the deep injection specification, where material is placed through tubes rather than through the slab.

Density, and therefore load. AP Lift 440 is a 4 lb foam at 80 psi free-rise compressive strength. AP Lift 475 is a 4.75 lb foam at 110 psi. The heavier grade also expands less, 15 times against 18, so the same void takes more material. Step up to 475 when the load or the lift depth is beyond what 440 is specified for.

It is a 4.75 lb foam. Published free-rise values are 110 psi compressive strength, or 15,800 psf, 100 psi tensile strength, or 14,400 psf, and 55 psi shear strength, or 7,920 psf, at a nominal cured density of 4.75 pounds per cubic foot. Flexural strength is 165 psi and the foam is 91.3 percent closed cell. Confined beneath a slab the foam reaches a higher density and higher strength than these free-rise figures.

They are compressive and shear values measured at three levels of confinement, labelled 1.5x, 2x and 3x on the data sheet, running from 171 psi compressive at 1.5x up to 406 psi at 3x. The data sheet does not define what the multiplier is measured against, so confirm the basis with Technical Services before using these values in a submittal.

The technical data sheet publishes an unconfined expansion of 15 times its liquid volume, the lowest of the grades published so far in this line. Unconfined is a laboratory free-rise figure. Under a slab or in confined ground the foam is compressed, so real expansion is lower and the resulting density is higher. Plan material quantities from the grade you are actually specifying.

Yes, and that is what the deep injection specification covers. Alchatek publishes CSI Section 02 55 00, the Deep Lock method of void fill, stabilizing soil and lifting pavement or concrete structures through injection pipes or tubing, written around AP Lift 475. It is in the downloads on this page, with the field procedure. Treating soil at depth rather than only the void directly under a slab is a different design problem, so bring Technical Services in early.

Alchatek publishes a technical document on polyurethane-stabilized ballast that names AP Lift 475 as the resin system developed for reinforcing and stabilizing loose bulk ballast stone on railway tracks. It is in the downloads on this page. Track work has its own loading, access and approval requirements, so treat that document as the starting point for a conversation with Technical Services rather than a specification you can issue as it stands.

The data sheet publishes 90 percent of full strength in about 15 minutes, which is why slab lifting is generally described as same-day work rather than a multi-day cure. Confirm return to service for your loading and conditions with Technical Services.

Both. The foam expands into voids and weak ground beneath the slab, compresses and densifies that soil as it expands, then cures into a closed-cell structural mass that carries load. Lifting the slab without addressing the ground beneath it is what lets a slab settle again.

The data sheet lists supplemental sinkhole remediation, and the word supplemental is doing real work in that phrase. The foam fills voids and densifies loose ground as part of a remediation designed by an engineer who has characterised the sinkhole. It is not a stand-alone sinkhole repair. Bring Technical Services into the design early.

A two-component proportioner with material heaters, plus a slab lifting gun for slab work, or injection tubing and pipe for deep injection. This is not a product that can be poured or hand mixed. The two sides are heated, metered, and mixed at the gun.

The reaction is temperature dependent. The data sheet gives equipment settings of 100 degrees F on the A side, 110 degrees F on the B side, and 105 degrees F at the hose. Those are material temperatures at the machine, not air temperature limits for the job site.

AP Lift 475 is certified to NSF/ANSI/CAN 61 and 372. The listing carries use restrictions, including a limit on how much of the total surface area may contact water, a minimum tank size, and a maximum surface-area-to-volume ratio, and it is not intended for pipe application. Read the certificate for the full conditions and confirm the listing is current before specifying.

The data sheet publishes a shelf life of 24 months in unopened containers stored between 50 and 80 degrees F. Both sides should be kept sealed and within that range.

The product page shows a 500-gallon unit, a matched pair of A-side and B-side containers. Confirm currently available unit sizes with Alchatek before ordering.

Proof & Verification

APLIFT475-PB-01

CVS Pharmacy Soil Stabilization

Developers working on a new CVS Pharmacy in Orlando, Florida, encountered critical soil stability issues during the construction process.
View case study

APLIFT475-PB-02

Slot 2: Performance Data Point or Credential

empty, Alchatek to supply
Case Studies

APLIFT475-PB-03

Slot 3: Documentation Reference

empty, Alchatek to supply
Case Studies

Heavy load, deep settlement, or ground that needs treating below the structure rather than just under the slab? Talk the grade and the injection method through before anything goes in.

For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.