Concrete Leveling & Stabilization · Structural Foam
AP Lift 460 Structural Polyurethane Foam
The 6 lb grade, and the heaviest foam in the AP Lift line, at 135 psi free-rise compressive strength. Note the numbering: 460 is heavier and stronger than 475, not lighter.
ISO 9001 Certified · Facility-wide quality management certification.
Heavy structural loads
Slab lifting & leveling
Void filling
Soil densification
On this page:
What it is
The 6 lb grade, the heaviest in the line
AP Lift 460 is a two component structural polyurethane foam used to lift concrete slabs, fill voids, and densify weak ground under the heaviest loads in the AP Lift range. It is a 6 lb foam, meaning a nominal cured density of 6 pounds per cubic foot, at 135 psi free-rise compressive strength. Density is the whole basis on which these products are selected, and this is the top of the range: above AP Lift 475 at 4.75 lb, AP Lift 440 at 4 lb, and AP Lift 430 at 3 lb.
One thing to get straight before specifying. The model numbers do not run in order of weight. AP Lift 460 is heavier and stronger than AP Lift 475, despite the lower number. Select by the density grade rather than by the number on the label. It is also hydro insensitive, so water in the ground does not stop the reaction.
Where it is used
What AP Lift 460 is used for
AP Lift 460 sits in the Concrete Leveling and Stabilization solution family, and is also used for soil stabilization work where the ground itself is the problem. The data sheet lists these uses:
Stabilizing soil
Lifting concrete slabs
Filling voids
Supplemental sinkhole remediation
The product page adds compaction grouting, fracture grouting, and wet compaction grouting and void filling.
Not sure whether the slab or the ground is the real problem? Start with settled concrete slabs if the concrete has dropped but the ground below is still solid, or soil instability beneath structures if the ground itself is weak or still moving. For settlement at a bridge approach, start with bridge approach settlement.
How it works
Why a heavier grade buys strength and costs volume
Small ports are drilled through the slab, the two components are heated and mixed at the gun, and the foam is injected beneath the concrete, where it expands, fills the void, compresses the surrounding soil, and then lifts the slab. The mechanism is the same across the AP Lift line. What changes with the grade is how much strength you get and how much material it takes to get there.
Density and expansion pull against each other. The 3 lb grades expand about 25 times their liquid volume; AP Lift 460 expands 12 times. So the heaviest grade delivers the highest strength in the line, and fills a given void with roughly half the volume yield of the lightest one. On a large void that difference decides the material order, and it is why the grade is a design decision rather than a preference.
The reaction also runs slower as the grade gets heavier, creaming in 5 seconds and reaching full rise at 32, which gives a crew more working time under a large slab. Cure still follows quickly: the data sheet publishes 90 percent of full strength in about 15 minutes. Confirm return to service for your loading and site conditions before scheduling traffic.
Technical specifications
Published properties
Cured foam, free rise
Property | Value | Method |
|---|---|---|
Density, free rise | 6 lb foam. Nominal 6 lb/ft³, range 5.75 to 6.25 lb/ft³ (92 to 100 kg/m³) | ASTM D1622 |
Compressive strength, free rise | 135 psi, or 19,400 psf (931 kPa) | ASTM D1621 / D1622 |
Tensile strength, free rise | 100 psi, or 14,400 psf (689 kPa) | ASTM D638 |
Shear strength, free rise | 75 psi, or 10,800 psf (517 kPa) | ASTM C273 |
Flexural strength | 189 psi, or 27,200 psf (1,303 kPa) | ASTM D790 |
Closed cell content | 87.3% | ASTM D6226 |
Water absorption | 1.30% | ASTM D2842 |
Shrinkage | Negligible | ASTM D1042 / D756 |
Dimensional change, thermal and humid aging | 1 percent, 0.25 percent volume | ASTM D2126 |
Expansion, unconfined | 12 times liquid volume | TDS |
Strength development | 90% of full strength in about 15 minutes | TDS |
NY-Panel result | Pass | TDS |
Cured foam, confined
Property | 1.5x | 2x | 3x |
|---|---|---|---|
Compressive strength, confined | 190 psi, 27,400 psf | 280 psi, 40,300 psf | 452 psi, 65,100 psf |
Shear strength, confined | 95 psi, 13,700 psf | 140 psi, 20,200 psf | 226 psi, 32,500 psf |
Confined values are what the foam does once it is compacted against soil and the underside of a slab, which is why they run well above the free-rise figures. The data sheet labels these levels 1.5x, 2x and 3x without stating what the multiplier is measured against, so confirm the basis with Technical Services before using them in a submittal.
Reaction profile at 105°F
Stage | Time | Method |
|---|---|---|
Cream time | 5 seconds | ASTM D7487 |
Tack-free time | 30 seconds | ASTM D7487 |
Rise time | 32 seconds | ASTM D7487 |
Liquid components
Property | A side | B side |
|---|---|---|
Specific gravity | 1.23 | 1.02 |
Weight per gallon | 10.25 lb | 8.5 lb |
Viscosity at 110°F | 200 cP (200 mPa·s), ASTM D4878 | |
Equipment settings, not ambient air temperature
Setting | Temperature | Note |
|---|---|---|
A-side material heater | 100°F (38°C) | Machine setting |
B-side material heater | 110°F (43°C) | Machine setting |
Hose | 105°F (41°C) | Machine setting |
Handling and storage
Property | Value | Method / Note |
|---|---|---|
Composition | Two component structural polyurethane foam, heated and mixed at the gun | TDS |
Storage temperature | 50 to 80°F (10 to 26°C) | TDS |
Shelf life | 24 months in unopened containers stored within the range above | TDS |
Packaging | 500-gallon unit, a matched A-side and B-side pair | Product page |
AP Lift 460 is a 6 lb foam and the heaviest grade in this line. Density is how these foams are graded, so a 3 lb, a 4 lb, a 4.75 lb and a 6 lb foam are different products for different loads, and the range above is the manufacturing tolerance on that grade, not a choice. Free-rise values are unconfined laboratory figures; confined beneath a slab the foam reaches a higher density and higher strength, which is what the confined table shows. This data sheet publishes no mix ratio. Temperatures in the equipment table are material temperatures at the machine, not air temperature limits for the job site, and no ambient application range is published for this product. Source: AP Lift 460 Technical Data Sheet, Rev. 1/20/2026, except where the Note column says otherwise. Properties vary with site conditions; confirm against the current data sheet before specifying.
Downloads
Data sheets and procedures
Technical Data Sheet (TDS)
Published properties · PDF
Safety Data Sheet, Part A
AP 400 Series A side · PDF
Safety Data Sheet, Part B
AP Lift 460 B side · PDF
Procedures, Slab Lift Process
Field procedure · PDF
Slab Lifting Brochure
Request the brochure · Short form
Assembling a submittal package or comparing products? Every TDS, SDS, spec, and certificate lives in the central Downloads library. For a specification naming AP Lift 460, contact Technical Services.
Compatible equipment & accessories
What you need to install AP Lift 460
Two-component proportioner with material heaters, required. AP Lift 460 cannot be poured or hand mixed. View proportioners
MixMaster Pro slab lifting gun, the standard gun for slab work across the AP Lift line. View gun
PX-7 slab lifting gun, the alternate gun option. View gun
3/8 inch hammer-in injection ports, the family-standard port. View ports
Alchatek Surface Guard 125, protects finished surfaces during injection. View accessory
Alchatek Pump Flush, reusable, biodegradable pump flush for shutdown. View flush
Alchatek Soak 130, cured-polyurethane cleaning solvent. View solvent
Related articles & guides
Learn the method behind the product
Lifting Foam Density and Expansion
Grade selection
Concrete Leveling with Polyurethane Foam - How Strong is Strong Enough?
Strength benchmarks
Concrete Leveling with AP 430, 440 and 475
Product comparison
Frequently Asked Questions
Stabilizing soil, lifting concrete slabs, filling voids, and supplemental sinkhole remediation, under the heaviest loads in the AP Lift range. It is the 6 lb grade, specified where the structural demand is beyond what the lighter grades are rated for.
Yes, and the model numbers do not tell you that. AP Lift 460 is a 6 lb foam and AP Lift 475 is a 4.75 lb foam, so 460 is the heavier and stronger of the two despite the lower number. Free-rise compressive strength is 135 psi for 460 against 110 psi for 475. Select by the density grade, not by the model number.
Yes. At a nominal 6 pounds per cubic foot it is the heaviest grade Alchatek publishes in this line, above AP Lift 475 at 4.75 lb, AP Lift 440 at 4 lb, and AP Lift 430 and 430 Fast at 3 lb. Heavier is not automatically better: the heavier the grade, the less it expands, so material quantities rise.
It is a 6 lb foam. Published free-rise values are 135 psi compressive strength, or 19,400 psf, 100 psi tensile strength, or 14,400 psf, and 75 psi shear strength, or 10,800 psf, at a nominal cured density of 6 pounds per cubic foot. Flexural strength is 189 psi and the foam is 87.3 percent closed cell. Confined beneath a slab the foam reaches a higher density and higher strength than these free-rise figures.
They are compressive and shear values measured at three levels of confinement, labelled 1.5x, 2x and 3x on the data sheet, running from 190 psi compressive at 1.5x up to 452 psi at 3x. The data sheet does not define what the multiplier is measured against, so confirm the basis with Technical Services before using these values in a submittal.
The technical data sheet publishes an unconfined expansion of 12 times its liquid volume, the lowest in the line. Density and expansion move in opposite directions across these grades: 25 times for the 3 lb foams, 18 for the 4 lb, 15 for the 4.75 lb, and 12 here. A heavier grade buys strength and costs volume, so material quantities have to be planned from the grade you are actually specifying.
The data sheet publishes 90 percent of full strength in about 15 minutes, which is why slab lifting is generally described as same-day work rather than a multi-day cure. Confirm return to service for your loading and conditions with Technical Services.
Both. The foam expands into voids and weak ground beneath the slab, compresses and densifies that soil as it expands, then cures into a closed-cell structural mass that carries load. Lifting the slab without addressing the ground beneath it is what lets a slab settle again.
The data sheet lists supplemental sinkhole remediation, and the word supplemental is doing real work in that phrase. The foam fills voids and densifies loose ground as part of a remediation designed by an engineer who has characterised the sinkhole. It is not a stand-alone sinkhole repair. Bring Technical Services into the design early.
A two-component proportioner with material heaters, plus a slab lifting gun. This is not a product that can be poured or hand mixed. The two sides are heated, metered, and mixed at the gun, then injected through small ports drilled in the slab.
The reaction is temperature dependent. The data sheet gives equipment settings of 100 degrees F on the A side, 110 degrees F on the B side, and 105 degrees F at the hose. Those are material temperatures at the machine, not air temperature limits for the job site.
The data sheet publishes a shelf life of 24 months in unopened containers stored between 50 and 80 degrees F. Both sides should be kept sealed and within that range.
Not one written around this grade. Alchatek publishes CSI Section 31 43 00 for concrete raising and void filling with AP Lift 430 and 440, and CSI Section 02 55 00 for deep injection with AP Lift 475. If you need AP Lift 460 named in a specification, contact Technical Services rather than substituting it into a specification written for another grade.
The product page shows a 500-gallon unit, a matched pair of A-side and B-side containers. Confirm currently available unit sizes with Alchatek before ordering.
Proof & Verification
Heavy structural load, and not sure whether the top grade is the right one or just the most expensive? Talk the grade, the volume, and the ground through before anything goes in.
For documentation, see the data sheets above or reach Technical Services. To purchase, find an authorized distributor or a qualified contractor.