Pat Mayse Dam Conduit Leak Sealing

Project photo: Pat Mayse Dam Conduit Leak Sealing
Alchatek
Case StudyLeak Sealing
Discharge conduit, Pat Mayse Dam Paris, Texas

Pat Mayse Dam
Conduit Leak Sealing

Gerace Construction was contracted to repair and seal leaks in the discharge conduit at the Pat Mayse Dam, under USACE oversight requiring a manufacturer's representative on-site during grout injection.

Injection hole depth
12in
Product
Spetec F400
Download as PDF
I · The Problem
Case Study  ·  01
01

What made this job
difficult.

Discharge conduit, Pat Mayse Dam
Paris, Texas

The primary challenge was to stop active water leaks within the concrete conduit pipe. A site visit identified the locations of cracks and weeps, as documented in the photo report included in the specification. The photos showed typical leaking monolith joints on the sides and top of the structure, as well as leaking monolith cracks.

Key Condition
These leaks required a solution that could effectively seal actively flowing water in both vertical and horizontal orientations.
The Constraint
USACE oversight
Manufacturer's rep required on-site
The U.S. Army Corps of Engineers required a qualified manufacturer's representative on-site during all grout injection, and the leaks had to be sealed against actively flowing water.
At a Glance
12in
Drill hole depth
45degrees
Drill angle
II · The Solution
Case Study  ·  02
02

What was specified,
and how it went in.

Spetec F400

Alchatek proposed the use of Spetec F400, a flexible polyurethane grout, to address the leaking cracks. The plan included supplying the necessary materials, equipment, and a qualified manufacturer's representative to supervise the installation.

The Material
Spetec F400
Flexible polyurethane grout
A flexible polyurethane grout used with Alchatek Gen Cat to control reaction time.
The Method
01
Prepare
Injection ports were installed along the identified cracks and weeps in the concrete pipe; holes approximately 12 inches deep were drilled at a 45-degree angle.
02
Inject
Spetec F400, along with Alchatek Gen Cat, was injected through the installed packers using a suitable pump, beginning at the lowest packer for vertical joints or cracks and working upwards.
03
Finish
Re-injection was performed to ensure all voids were sealed, packers were re-injected with water, ports were removed and cut flush, and packer holes were filled with epoxy paste.
III · The Proof
Case Study  ·  03
03

What the result was,
and what confirmed it.

The Outcome

The Alchatek solution, implemented by Gerace Construction, effectively sealed the cracks and stopped the leaks in the Pat Mayse Dam discharge conduit. The on-site presence of a qualified manufacturer's representative ensured the proper application of the product, meeting the requirements of the USACE.

The Outcome
The project was completed in accordance with the specifications, resulting in a successful repair.
Start the Conversation
Send us the job.
We will send back an approach.

Send us the soil report or the failure photos and Technical Services will return a written approach within two business days.

Alchatek Technical Services
404 · 618 · 0438 ALCHATEK.COM
info@alchatek.com
Alchatek

Alchatek manufactures polyurethane resins, chemical grouts, and injection equipment for infrastructure repair: leak sealing, soil stabilization, concrete lifting, and seawall repair. Headquarters in Tucker, Georgia, with a bonded warehouse in Reno, Nevada.