Back to Blog

Sealing Leaks in a Historic Brick Wall with Spetec AG200

The Challenge: Water Infiltration in a Historic Brick Wall

Alchatek’s Leak Seal division often assists customers with some interesting jobs. Such was the case when the Alchatek technical team was called in to consult with a contractor who was sealing a leak in a historic district below-grade, multi-course brick wall. As is often the case with below-grade, historic spaces, water infiltration was unsightly, gave off a musty odor, and was damaging to finishes. This was a very old brick wall, approximately 8 x 15 feet in size and at least three courses thick. The owner wanted to find a way to waterproof this vintage brick structure while at the same time preserving its unique appearance. In addition to the water flow issue, the leaks were causing mold and mildew on the walls.

The Solution: Spetec AG200 Injection Resin

Alchatek proposed injecting Spetec AG200, an elastic acrylic injection resin, into the cementitious grout between the bricks where the water was migrating through.

The Injection Process

Three areas of the wall were identified for treatment before the injection process began. After Spetec AG200 was injected into the existing cementitious grout around the bricks in two of those areas, the third area no longer required injection due to the efficacy of the Spetec AG200.

The Results: A Dry Wall with Its Historic Character Intact

In addition to stopping the water flow, sealing the leaks made it possible for the bar owner to keep the walls clean in appearance. See the treated area of the brick wall vs. a non-treated area.

Untreated vs treated historic brick wall, showing efflorescence and leaks removed after Spetec AG200 injection

Want more information on curtain grouting with polyurethane?